亚洲精品一本知道高清乱码|日韩一区二区三区在线观看不卡|亚洲精品美女在线观看播放|久久一本精品久久久久99|亚洲 一区 精品 在线

Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

Fixed a wall-mounted ultrasonic flowmeter

4固定壁掛式超聲波流量計(jì).jpg
  • 4固定壁掛式超聲波流量計(jì).jpg
ZWS series - 100 f1Fixed a wall-mounted ultrasonic flowmeterIs imported, integrated circuit pasted o…

Description:

Products overview:

ZWS series - 100 f1Fixed a wall-mounted ultrasonic flowmeterIs imported, integrated circuit pasted on the circuit complete digitization, integration, and improve the measuring accuracy and stability, greatly reducing the breakdown maintenance, is the current domestic advanced technology, performance, stability, easy installation and Z Z of a low power flow measuring instrument, according to many years of experience, and constantly updated products, the new version of the ultrasonic flowmeter its powerful functions, operation speed, strong anti-interference ability, cycle sampling frequency up to 128 times, are widely used in industrial field of online measurement of various kinds of liquid flow rate.

Second, the working principle:
ZWS series - 100 f1Fixed wall hung at the ultrasonic flowmeter using low voltage, pulse jet lag principle, the use of high precision and super stable double balance emission signal difference, difference receive digital detection technology to measure the direction of the downstream and upstream sound wave transmission time, according to calculate the velocity of jet lag.
When ultrasonic beam propagation in the liquid, the flow of the liquid produce small changes will make the travel time, the travel time is proportional to the liquid flow rate, the change of zero flow, two sensors in the time required to transmit and receive sound waves is exactly the same techniques for actual measurement of zero flow (*).Medium flow, the flow direction of sound wave transmission time is greater than in the direction of flow of sound wave transmission time.
Applications:
ZWS series - 100 f1Fixed a wall-mounted ultrasonic flowmeter can measure the fluid is water, sea water, or oil, uniform liquid slurry, conduct electricity or not, corrosive or no corrosive liquid can be measured.ZWS - 100 - f series are widely used in industrial field of each kind of liquid in the online traffic measurement, which the host is divided into standard wall hanging type, tray type, hanging type explosion-proof, sensors can be divided into outer bound type, insert type, pipe sections, etc., the use of different field in order to meet user needs.

Four, basic configuration:

ZWS series - 100 f1Basic configuration of fixed wall ultrasonic flowmeter to host (display) + sensor (external or insert) host has a standard wall hung, plate mounted and explosion-proof optional sensor is divided into external clip-on sensor and insertion type sensor;Outer clamp type sensor characteristic is in don't want to destroy pipeline applications, installation construction, simple operation without any external clip-on sensor installation is to put the two sensor apply is on the outer wall of pipeline, not contact with the current body.Sensor between the outer wall of pipeline and the surface coated with lotus root mixture (vaseline), transducer with the special tie (factory equipped with) bound on the pipeline.Insert type sensor is characterized by stable running, insert type sensor is installed in the line open a 20 mm diameter hole, the sensor fixed on the pipe hole, let the sensor ring part and measured liquid contact, our company research and development of technology can make the insert sensor online not water supply installation, is easy to maintain, corrosion.

Five, the main features:
1, high reliability, high performance, good applicability, full display in Chinese.
2, day, month and year flow accumulation function, can record run 64 days before the operation, the first 64 months, the first five years of accumulated flow operation.
3, on, power management function, can record, electricity and traffic on 64 times before, can be manually or automatically compensate to reduce flow losses.
4, effectively overcome the wall of the ultrasonic signal attenuation and the rough surface of the pipe to scattering of ultrasonic signal from surface reduce the energy consumption of ultrasonic signal.
5, improved flow measurement accuracy, especially suitable for pipe flow measurement.
6, unique disassembly with pressure, does not affect the normal production, at any time to complete the on-line replacement and maintenance.
Six, the technical parameters:
1, measuring liquid: water, sea water, alkali and other single * body, turbidity is less than 10000 PPM, particle size less than 1 mm;
2, material: steel, cast iron, PVC pipe ultrasonic can penetrate the full package, such as dense texture, and no serious corrosion and scaling allows thin layer compact lining;
3, pipe lining material: rubber, epoxy asphalt, glass fiber reinforced plastic, mortar, etc., or without lining;
4, pipe diameter range: DN15mm to 6000 mm, inserted type sensor used by DN25mm ~ 6000 mm;
5, velocity range: - 32 m/s ~ 0 ~ + 32 m/s, two-way flow;
6, the accuracy of the quasi: display value plus or minus 1.0% (standard conditions).Configuration plug-in sensor accuracy can reach 0.5%;
7, linear degree: 0.5%;
8, signal output: 4-20 ma, or 0 to 20 ma, the RS - 485;
9, the sense organ, is divided into external clip-on and plug-in.Standard configuration for external clip-on.Insert type sensor zui high work pressure of 3 mpa;
10, straight long: upstream > 10 D, 5 D > downstream from pump discharge > 30 D (D: diameter);
11, the display mode: 2 * 20 characters LCD display, with LED backlight.
12, protection grade: IP65;
13, explosion-proof grade: Exd Ⅱ BT4;
14, the electric source: AC220V, DC8 or AC7 ~ 30 v ~ 36 v;
15, environment temperature/humidity: host - 20 ℃ ~ + 80 ℃;Sensors - 20 ℃ ~ + 80 ℃ or - 20 ℃ ~ + 160 ℃ is optional, the sensor can work of flooding, the water depth is less than 2 m.
Seven, host:
1, the accuracy is better than 1%, the repeatability is 0.5%;
2, for 500 ms measurement cycle;
3, backlit LCD can display instantaneous flow and cumulative amount at the same time, the instantaneous heat and accumulative total quantity of heat, velocity, time and other data;
4, 4 ~ 20 ma output current, or 0 to 20 ma, such as impedance 0 ~ K, accuracy of 0.1%;
5, which can realize heat measurement or one dual purpose;
6, automatic recording, 64 month before, 64 days before the five years of accumulated flow;
7, automatically record before 64 calls and interruption time and flow rate, can be manually or automatically fill amount, reducing the loss of user traffic;
8, automatic record 64 days before the working state of the flow meter is normal;
9, the data interface to factory is configured to RS - 232, equipped with RS - 232 / RS - 485 converter can be turned into RS - 485 after way;
Eight, special cable:
Models for SEYV75-2 block type, single can be extended to 500 meters, at the same time, pay attention not to parallel with high voltage cable, as far as possible to avoid the frequency converter.
Nine, pipes:
1, pipe: steel, stainless steel, cast iron, cement pipe, PVC, aluminum, copper, glass fiber reinforced plastic all quality of pipes, such as the lining is allowed
2, pipe inner: 15 mm to 6000 mm;
3, straight pipe sensor installation points satisfy the 10 D, upstream downstream 5 D, 30 D to the pump discharge mean diameter (D);
Ten, measuring medium:
1, type: tap water, sea water, industrial sewage, various oil, acid alkali, alcohol, beer can support such as ultrasonic single homogeneous liquid;
2, temperature: 0 ℃ ~ 160 ℃;
3, turbidity, 10000 PPM or less, and the bubble content is small;
4, velocity: 0 ~ + 30 m/s;
5, flow: positive and reverse bidirectional measurement, and can be measured net flows;
Eleven, working environment:
1, the temperature of the host: - 30 ℃ ~ 80 ℃;
2, flow sensor temperature: - 40 ℃ ~ 160 ℃;
3, temperature sensor temperature: selected according to user's requirements;
4, host, humidity: 85% RH;
5, flow sensor, humidity: can work immersed depth of 3 m or less;
6, fixed hanging type ultrasonic flow power: AC220V DC8 ~ 36 v or AC7 ~ 30 v.
Twelve, sensor installation steps:
1, choose to have enough length of straight pipe, a new pipeline, no rust, easy to operate.
2, clear the clutter and on the pipeline corrosion, using grinding Angle grinder abort rust.
The launch of 3, on the sensor surface with plenty of coupling agent (such as butter, vaseline, etc.), besmear coupling 4, mixture rule out is the purpose of the sensor emission surface and air between the external surface of the pipe.
5, special remind: should avoid sand and debris into the middle.
6, horizontal pipe wall upside may remain some bubble, in the selection of pipe should be installed on the tangent to the pipe on the side of a vertical surface.
13, check the installation:
Users after installed sensors to inspection on the following items: receive signal strength and goodness of Q value, jet lag, estimates the liquid velocity and ratio of signal transmission time.Only in this way can flow meter and stable operation, accurate measurement.
14, signal intensity:
Refers to the received signal strength after amplification of ultrasonic signal amplitude, with 3 digits said: [000] is not detected any signal;[999] zui refers to the received signal.
Although signal between 500-999 meter can work, but the stronger signal strength can get good results, so users should adjust the signal of the sensor to receive to zui.
Suggestions according to the following methods of operation to get larger signal strength:
1, if measured flow numerical instability, when signal strength is below 700, to choose a better location measurement.
2, the outer surface of the polishing pipe carefully, some slightly more coupling agent.
3, slightly adjust the relative position of the sensor at the same time observe the flow meter of received signal strength, parked in the signal zui big place, at the same time also want to check if the distance between the sensor can satisfy the demands of M25 window display.
Signal quality (signal good degrees) :
Flowmeter signal quality is to use Q value.Q value means the higher signal-to-noise ratio (SNR) of an acronym, of course, is more accurate, the measured data of the Q values should be between 600-900 range, the higher the better.

15, use notice: 
1, zero flow rate checks 
Around when the pipeline fluid static, without strong magnetic field interference, strong vibration, header shows zero, automatically set zero point at this time, eliminate the zero drift, the runtime must to remove small signal, usually 5% flow is less than the full process flow, automatic removal.Zero at the same time also can adjust menu. 
2, instrument panel keyboard operation 
Before start the meter running, the first to set parameters effectively, for example, using the system, installation, pipe diameter, pipe wall thickness, pipe material, pipe roughness, fluid type and the distance between two probes, velocity of flow unit, small speed, big z z, etc.All parameters input correctly, instrument can display correctly the actual flow value 
3, flowmeter calibration 
Guarantee the accuracy of flowmeter, we conduct regular check, usually we use higher precision direct comparison, portable flowmeter: using the test data to compute error = - standard/standard measurements, using relative error calculation, correction factor, satisfy error of measurement error of plus or minus 2%, can meet the measurement requirements.This simple and convenient operation, can effectively improve the accuracy of measuring.

16, optional tied outside sensors:

Outer bound type sensor is to bundle sensors directly on the outer surface of the pipeline under test so as to realize the flow measurement of an installation, has has nothing to do with the pipe diameter, installation is simple, no production, no pressure loss, etc.

Technical parameters

S1 standard type

Standard M1

Standard type L1

High temperature type S1H

High temperature type M1H

Suitable diameter

DN15~DN100

DN50~DN700

DN300~DN6000

DN15~DN100

DN50~DN700

Material is qualitative

ABS

Special high temperature material

Working frequency

1MHz

Installation method

V (N, W) method

V, and the method of Z

The Z method

V (N, W) method

V, and the method of Z

calibration

The whole machine matching calibration

magnetic

There are

There is no

Suitable temperature

0 ℃ ~ 70 ℃

0 ℃ ~ 160 ℃

Protection grade

IP68 (can work immersed depth of three meters or less)

Overall dimensions

45 * 30 * 30

60 * 45 * 45

80 x 70 x 55

90 x 85 x 24

90 * 82 * 29

Quality (g/on)

75

250

650

94

150

Medium variety

Water, sea water, sewage, alcohol, such as various oil can conduction ultrasonic single, uniform and stable liquid.

Medium turbidity

20000 PPM or less and the bubble content is small

Apply pipe

Carbon steel, aluminum, stainless steel, cast iron, copper, PVC, FRP uniform quality of pipes, such as the lining is allowed.

Pipe lining material

Epoxy asphalt, rubber, mortar, polypropylene, polystyrene, bakelite, teflon, etc.

Signal cable

SEYV75 - type 2 special shielded cable, single can be extended to 300 meters, wiring cable should be with metal casing to increase anti-jamming, and pay attention to the cable don't parallel with high voltage cable, as far as possible to avoid the frequency converter and other interference sources.

The 17th and optional inserted into the sensor:

Insert type sensor is refers to the hole on the pipeline to be tested using special tools in online punching without shutdown, so direct contact with the sensor and measured medium so as to realize the flow measurement of an installation, the sensor has solved the outer bound type sensor in measuring scale thick line to receive the signal and measurement signal attenuation problem for a long time, has not stopped production installation, maintenance free, has nothing to do with the pipe diameter, pressure loss, etc.
Pipe material is carbon steel or stainless steel can be directly welded installation, for not directly welded pipe, such as cast iron, cement, glass fiber reinforced plastic, PVC pipe should be equipped with the factory production of special pipe hoop before installation, to prevent leaking, when you place an order, please provide accurate measured pipe diameter or circumference.

Technical parameters

Standard insert type B (into)

Insert type C (inclined plug-in, very common)

Extended inserting type B (cement works)

Suitable diameter

DN80mm above

The material

Ball valve and sheath maerial: 316 l stainless steel;The ball valve base: plain carbon steel (stainless steel optional)

Working frequency

1MHz

Apply pipe

Carbon steel, stainless steel, cast iron, copper, PVC, aluminum, glass fiber reinforced plastic and cement pipe pipe, such as the lining is allowed

Note: 1, carbon steel, stainless steel can be directly welded (stainless steel pipe must adopt stainless steel base, please note when you place an order).

2, other pipe with pipe hoop before installation (coupling material: carbon steel, when placing order, please provide the accurate pipe diameter or circumference).

installation

The Z method

Suitable temperature

- 40 ℃ ~ 160 ℃

The size of hole

Ф 19 mm (with manufacturers provide dedicated openings for a installation, can be realized with no production installation)

Classes.

1.6 MPa (< 0.8 MPa pressure when installation)

Protection grade

IP68 (can work immersed depth of three meters or less)

The installation space

Wall to wall or 550 mm

Wall to wall or 360 mm

Wall to wall or 700 mm

Long degrees

186mm

228mm

330mm

Medium variety

Water, sea water, sewage, alcohol, such as various oil can conduction ultrasonic single, uniform and stable liquid.

Medium turbidity

20000 PPM or less and the bubble content is small

Signal cable

SEYV75 - type 2 special shielded cable, single can be extended to 300 meters, wiring cable should be with metal casing to increase anti-jamming, and pay attention to the cable don't parallel with high voltage cable, as far as possible to avoid the frequency converter and other interference sources.


Eighteen, selection of coding:

Type no.

code

The name says

ZWS-100F

-

-

-

-

-

-

-

-

In the ultrasonic flowmeter (wei measurement and control)

The host style

1


wall

2


explosion-proof

3


Disc mounted

Pipe diameter


DN


DN15-DN6000mm

Optional sensor


S1


S1 standard type sensor (bound type)

M1


Standard M1 type sensor (bound type)

L1


Standard type L1 sensor (bound type)

S1H


High temperature type sensor S1 (bound type)

M1H


High temperature M1 type sensor (bound type)

C


Insert B type sensor (plug-in)

G


DN15 - DN1000mm (KNN)

Input mode


0


No input

1


4-20 ma input

2


Pt100 platinum resistance input

Output way


0


There is no output

1


4-20 ma output

2


Relay output

3


OCT output

4


RS-232

5


RS-485

Power supply


D


220VAC

F


24VDC

Signal cable


LN


5 m x 2

Example:,ZWS-100F1-200-M1-0-1-A-L5; 
Explanation: the pipe diameterDN200mm,The standard standardM1Sensors, no input,4-20mAThe output,220VACPower supply, signal cable5mX 2。

In the 19th, design selection and ordering information:

1, products: specify model standard, if any, please live in wei sales hotline advisory prices, details!

2, technical support, if not specified product specifications, please put the working condition of requirements, design drawings, technical specifications, to us.

3, product orders for parameters: size (DN), nominal pressure (Mpa), temperature (℃), the connection way (flange, etc.) to the clamp.

4, offer confirmation: the company provide price list and technical standard specifications to customers to confirm, in the technical aspects to confirm before you draw up a contract.

5, quality requirements, quality standards, the supplier is responsible for the quality conditions: according to the relevant state quality standards.

After-sales service commitment:

1, from the date of signing of the contract, I in the way provided for products of the company offers free maintenance and maintenance service, commitment to lifelong maintenance service;

2, jiangsu wei measurement and control instrument co., LTD. Sales manager will be in regular contact with customers, understand the usage of products, and solve the problems of the customers to use in the process of produce, free of charge to provide technical support;

3 the man-made damage is found, the warranty period, our company is responsible for the maintenance, and the resulting maintenance fee;

4, product quality problems or are not satisfied with product, the user can choose unconditional return, wei tt&c don't charge any fees, appear quality problem, bear the freight back and forth.



Browse: