亚洲精品一本知道高清乱码|日韩一区二区三区在线观看不卡|亚洲精品美女在线观看播放|久久一本精品久久久久99|亚洲 一区 精品 在线

Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

Pipeline electromagnetic flowmeter

1管道式電磁流量計02.jpg
1管道式電磁流量計01.png
1管道式電磁流量計03.png
  • 1管道式電磁流量計02.jpg
  • 1管道式電磁流量計01.png
  • 1管道式電磁流量計03.png
Pipeline electromagnetic flowmeter is an alias of electromagnetic flowmeter, the pipeline is connect…

Description:

Products overview:
ZW - LDE seriesPipeline electromagnetic flowmeterIs a kind of measuring tube according to Faraday's law of electromagnetic induction induction of conductive medium volume flow meter, MCU embedded technology, digital excitation, at the same time in the electromagnetic flow meter adopting CAN field bus, the technology to meet the domestic advanced level.Shows the scene of the meet at the same time, also can output 4 ~ 20 ma current signal for records, adjust and control, meter in addition to the general conductive liquid flow can be measured, can also be measured liquid-solid two phase flow, high viscosity fluid and salt, strong acid, strong alkali liquid volume flow.
Second, the working principle:
ZW - LDE seriesPipeline according to the principle of Faraday electromagnetic induction of electromagnetic flowmeter, with the sounding pipe axis and the magnetic field lines in the vertical tube wall installed on a pair of detecting electrodes, when conducting liquid along the measuring tube axis movement, conductive liquid cutting lines of magnetic force induced electric potential, the induction electric potential by two detection electrodes detection, numerical size and flow into a direct ratio, its value is: E = KBVD type:
E - induction electric potential;
K - factor related to the magnetic field distribution and the axial length;
B - magnetic induction intensity;
V - conductive liquid average flow velocity;
D - electrode gap;(the measuring tube diameter)
Sensor will be induced potential E as traffic signal, sent to the converter, amplifying, transform filter with a series of digital processing, USES dot matrix LCD display with backlight instantaneous flow and cumulative flow.Converter has 4 ~ 20 ma output, alarm output and frequency output, and is equipped with RS - 485 communication interface, and supports HART and MODBUS protocol.
Applications:
ZW - LDE seriesPipeline electromagnetic flowmeter has a wide range of USES, the application in the chemical industry, environmental protection, textile, metallurgy, mining, pharmaceutical, paper making, water, food, sugar, brewing and other industries in the process piping conductive medium of liquid flow metering;In addition to measuring general conductive liquid, according to user's special needs, can also be measured conductive liquid solid two phase flow, high viscosity liquids and salts, such as strong acid, strong alkali liquid flow. 
Four, structural components:
1, the sensor:
Sensor is mainly composed of measuring tube and electrode, excitation coils, iron core, magnetic yoke and shell. 
A, measuring catheter: by stainless steel tube, the lining and the connecting flange, as the carrier of measured liquid measurement working conditions on site. 
B, measuring electrode: installed in the measuring tube inside wall, and the axial direction perpendicular to a pair of electrodes to measure liquid signal generation. 
: c, excitation coil in a magnetic field measurement of intraductal two excitation coil. 
D, iron core and magnetic yoke: the excitation coil of the magnetic field generated import liquid, and the magnetic circuit. 
E, shell: instrument packaging. 
2, the converter:
Is the smart secondary table, it will flow signal amplification processing??Single chip microcomputer after the operation, can display flow, total amount, and can output pulse and analog current signal, used in the measurement or control of fluid flow.
3, product assembly form:
It into a shape and size in two forms. 
A, a shape: mounted sensors and switches. 
B, size: separation installation sensor and converter, through the connecting cable form flow metering system. 
C, in order to adapt to the measurement demands of the different medium, the lining of sensor and electrode materials can have many choices.
Five, the main features:
1, instrument structure is simple, reliable, have no moving parts, long working life.
2, no closure choke parts, there is no pressure loss and flow blocking phenomenon.
3, no mechanical inertia, fast response and good stability, can be applied to automatic testing, adjusting and SPC system.
4, the measurement precision is not affected by the type of measured medium and its temperature, viscosity, density, the influence of physical parameters such as pressure.
5, adopt ptfe or rubber lining material and Hc, Hb, 316 l, the different combination of electrode materials such as Ti can adapt to the needs of different medium.
6, with pipeline, plug-in, such as a variety of flow meter type.
7 block, using EEPROM memory, measuring operational data storage safe and reliable protection.
8, integration and separation of two kinds of model.
9, high-definition LCD backlit display.
Six, the technical parameters:
1, precision instrument: pipeline magnitude 0.5, 1.0;Plug in 2.5 on the Richter scale are unlikely.
2, measuring medium: conductivity is greater than 5 mu S/cm of various liquid and liquid-solid two-phase fluid.
3, velocity range: 0.2 ~ 8 m/s.
4, work pressure: 1.6 MPa.
5, environmental temperature: - 40 ℃ ~ + 50 ℃.
6, medium temperature: ptfe lining 180 ℃ or less;Rubber lining material 65 ℃ or less.
7, explosion-proof marks: Exmibd Ⅱ BT4.
8, explosion-proof number: GYB01349.
9, outside magnetic interference: 400 a/m or less.
10, shell protection: integration type: IP65;
In mold: sensor IP68 (5 meters underwater, rubber lining only);Converter IP65.
11, the output signal: 4 ~ 20 ma DC, load resistance Ω 0 ~ 750.
12, communication output: RS485 and CAN bus.
13, electrical connections: M20 x 1.5 internal thread, phi 10 cable hole.
14, power supply voltage: 90 ~ 220 v AC, 24 + / - 10% V.D C.
15, zui big power consumption: 10 or less va.
Seven, according to excitation methods of classification:
To produce a uniform constant magnetic field, it needs to choose a suitable way of excitation.Such as divided according to the field current mode, have a dc field, ac (or other frequency) power frequency excitation, low-frequency rectangular wave excitation and dual-band rectangular wave excitation.
1, the dc excitation
Dc excitation method with direct current (dc) or use a magnet to produce a uniform magnetic field is constant.The dc excitation transmitter is affected by the ac electromagnetic interference is very small, so you can ignore the influence of the liquid in the self inductance.But using dc magnetic field is easy to make by measuring the electrolyte fluid of the pipe is polarized, the electrolyte by electrolysis in the electric field, produce positive and negative ions, in under the action of electric field force, ran to the anode, anion cation ran to the cathode, which will result in positive and negative electrodes were surrounded by ions of opposite polarity, seriously affect the normal work of the instrument.So, dc excitation only commonly used for measuring the liquid electrolyte, such as the liquid metal flow of mercury (room temperature and high temperature of liquid steel, lithium, potassium), etc.
2, ac excitation
Industrial use of electromagnetic flowmeter, most used (50 hz) power supply power frequency ac excitation method to produce alternating magnetic field, to avoid the dc excitation on the surface of the electrode polarization interference.But the use of ac excitation will bring a series of electromagnetic interference problem, such as orthogonal interference, in-phase interference, zero drift, etc.).Ac excitation is now replaced by low frequency square wave excitation.
3, low frequency square wave excitation
Low frequency square wave excitation waveform has two values (positive - negative) and three values (positive - zero - negative - zero) two kinds, the frequency of power frequency usually 1/2 ~ 1/32.Low frequency square wave excitation can avoid orthogonal electromagnetic interference of ac magnetic field, power frequency interference caused by distributed capacitance, inhibition of ac magnetic field within the tube wall and fluid caused by eddy current, dc excitation polarization phenomenon.
Eight, the choice of installation environment:
In order to make the transmitter work stability, when choosing installation environment should be paid attention to the following requirements:
1, try to avoid strong ferromagnetic objects and concrete equipment of electromagnetic field (such as a big motor, transformer, etc.), so as to avoid the magnetic field of magnetic field effect sensor and traffic information.
2, should be installed in a dry and ventilated place, should not be in damp, easy seeper place of installation.
3, should try to avoid weathered, avoid environmental temperature is higher than 45 ℃ and relative humidity is more than 95.9%.
4, choose to facilitate maintenance and convenient place.
5, flow meter should be installed in the pump back end, never on the suction side of the installation;Valve should be installed in the downstream flow meters.
Nine, installation requirements:
The characteristics of the electromagnetic flowmeter measurement does not rely on traffic, if the line has some turbulence and vortex in the measurement area (such as elbow, tangential current limiting or upstream of half cut-off valve) has nothing to do with the measurement.If there is a steady state of the eddy current in the measurement zone will affect the stability of measurement and measurement precision, then you should take some measures to stabilize the velocity distribution:
1, increase the length of the straight pipe before and after;
2, using a flow stabilizer;
3, reduce the cross section measurement point.

10 and the matters needing attention during installation.
1, the axis of the measuring electrode must be similar to horizontal direction;
2, measuring the pipe must be completely filled with liquid.
3, less flowmeter zui ahead to have 5 * D for flow meter diameter (D) the length of the straight pipe, the rear zui to have less 3 * D for flow meter diameter (D) the length of the straight pipe;
4, the direction of fluid flow and the direction of arrow flowmeter;
Five should have can be damaged by vacuum meter, the pipe lining, special attention should be paid;
6, near the flow meter should be no strong electromagnetic field;
7, shall have plenty of space, near the flowmeter to installation and maintenance;
8, if measuring pipeline vibration, the flowmeter should be fixed on both sides of bearing when measuring the mixed liquid of different medium hybrid point and the distance between the flowmeter zui to have less 30 x D for flow meter diameter (D) the length of the cleaning and maintenance for the convenience of the flowmeter, should install bypass pipe.
Eleven, grounding protection, must pay attention to the following: 
1, sensor, converter should be separate grounding, never even on the motor, process piping, grounding resistance should be less than 10 ohms. 
2, sensor measurement of tube and shell, shielded wire, converter and secondary instrument must be grounded. 
3, sensors, converters, grounding on the scene, to the shield in the control room side of the secondary instrument grounding, not multiterminal grounding, lest introduced due to different potential interference. 
4, sensors installed in a metal tube, the sensor can be grounding wire connected to the pipe flange according to the requirement of the factory, the formation of reliable grounding instrument ground should be an independent site, can not share other electrical equipment grounding.

12, main technical data:

1, the whole machine and the technology of sensor data:

Execution standard

JB/T 9248—1999

Nominal diameter

15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000, 2200, 2400, 2600, 2800, 3000

High velocity

15m/s

precision

DNl5~DN600

Show the value of the: plus or minus 0.3% (velocity of 1 m/s or higher);Plus or minus 3 mm/s < 1 m/s (velocity)

DN700—DN3000

Plus or minus 0.5% of the value (velocity of 0.8 m/S or higher);Plus or minus 4 mm/s < 0.8 m/s (velocity)

Fluid conductivity

≥5uS/cm

Nominal pressure

4.0MPa

1.6MPa

1.0MPa

0.6MPa

6.3、10MPa

DNl5~DN150

DNl5~DN600

DN200~DN1000

DN700~DN3000

Special orders

The environment temperature

The sensor

- 25 ℃ - 10 to 60 ℃

Converter and a body

- 10 ℃ - 10 to 60 ℃

The lining material

Ptfe, chloroprene rubber, polyurethane, fep (F46), and network PFA

High fluid temperature

- size

70 ℃

The separation type

Poly (chloroprene rubber lining

80 ℃;120 ℃ (when ordering specify)

Polyurethane lining

80 ℃

Ptfe lining

100 ℃;150 ℃ (when ordering specify)

Fep (F46)

And network PFA

Signal electrode and the grounding electrode materials

Stainless steel 0 crl8nil2m02ti B, C, hartz hartz alloy alloy, titanium, tantalum, platinum/iridium alloy, stainless steel coated with tungsten carbide

Electrode institutions

DN300—DN3000

Connecting flange material

Carbon steel

Grounding the flange material

Stainless steel 1 crl8ni9ti

Import protection flange material

DN65—DNl50

Stainless steel 1 crl8ni9ti

DN200~DNl600

Carbon steel stainless steel 10 1 crl8ni9ti

Enclosure protection

DNl5 ~ DN3000 separation type rubber or polyurethane lining sensor

IP65 or IP68

Other sensors, bodily form separated type flowmeter and converter

IP65

Spacing (separation type)

Converter distance sensor is generally not more than 100 m

2, converter technology data:

The power supply

communication

85—265V,45—400Hz

dc

11—40V

Operation keys and display

touch-tone

Four film button can be set to choose all parameters, can also use a PC (RS232) of converter set programming;

3 rows wide Angle of view, wide temperature, with backlit LCD display;

Line 1 shows the flow value;

Line 2 show that flow units;

Line 3 shows total flow percentage, total quantity of forward, reverse, total difference, alarm, velocity of flow.

The magnetic key type

The selection of two magnetic key is used to display parameters and reset, use PC (RS232) on converter set programming;

2 rows wide Angle of view, wide temperature, with backlit LCD display:

Line 1: the magnetic key choice: display flow percentage, total quantity of forward, reverse, total amount, total difference, alarm, velocity of flow.

Line 2: display traffic.

Internal integrator

Total forward, reverse and total difference amount.

The output signal

One-way analog output

Complete isolation, load 600 d or less.When (20 ma);

Cap: 0-21 ma optional, each lmA;

Floor: 0-21 ma optional, each 1 ma;

Forward and reverse flow output way of programming.

Two-way analog output

The lower limit for.Or 4 ma, the other with one-way analog output.

The bidirectional pulse output

Two lines of the output corresponding to forward and reverse flow, 0 ~ 800 hz frequency, maximum of 1-800 hz optional, each IHz;

Square-wave or selected pulse width, pulse width limit selected 2.5 s, every 1 ms;

Passive isolation switch output transistor, can absorb 250 ma of current, voltage 35 v.

Two-way alarm output

Alarm (programming) high/low flow rate, air traffic control, fault state, positive, and reverse flow, analog outrange, pulse volume range, small pulse signal excision, output polarity optional;

With isolation protection switch output transistor, can absorb the current of 250 ma, withstand voltage 35 v. (with pulse output isolation)

Digital communications

RS232,RS485,HART

3, the choice of the lining:

The lining material

The main performance

Zui high medium temperature

Scope of application

- size

The separation type

Ptfe (F4)

Is a kind of plastic, stable chemical performance of boiling hydrochloric acid, sulfuric acid, nitric acid and aqua regia, strong alkali and a variety of organic solvents.Not resistant to high velocity fluid fluorine, oxygen, the oxygen corrosion.

70 ℃

100 ℃ 150 ℃ (special order)

1, strong corrosive medium such as strong acid, alkali.2, health, type of medium.

Fep (F46)

With F4, abrasion resistance, resistance to negative pressure ability is higher than the F4.

Same as above

Fluoropolymer and ethylene (Fs)

For maximum temperature was lower than those of ptfe, but the cost is low.

80 ℃

Poly (neoprene

1, has excellent flexibility, high break strength, wear-resisting performance is good.2, generally low concentration acid resistance, alkali, salt medium corrosion, oxidation of medium corrosion resistance.

80 ℃ 120 ℃ (special order)

Water, sewage and mud pulp weak up to wear and tear.

Polyurethane rubber

1, wear-resisting performance is extremely strong.

2, poor corrosion resistance.

80 ℃

Neutral strong wear of slurry, coal slurry and mud

4, import protection flange and the choice of grounding flange ring (or ground) :

The flange type

Comfortable with van

Grounding the flange ring (or ground)

Non-conductors is suitable for pipeline, such as plastic pipe, but has the grounding electrode sensor doesn't need.

Import protection flange

When the medium has strong wear.

5, the choice of electrode:

Electrode materials

Corrosion resistance and wear resistance

Stainless steel 0 crl8nil2m02ti

Used for industrial water, water, sewage with weak corrosive medium, such as applicable to petroleum, chemical, steel and other industrial sectors and, municipal, environmental protection and other fields.

Hartz alloy B

Below boiling point for all the concentration of hydrochloric acid have good corrosion resistance, resistant to sulfuric acid, phosphoric acid, organic acids and other non chloride acid, alkali, corrosion of non oxidizing salt solution.

Hartz alloy C

Non oxidizing acid such as nitric acid, mixed acid, or a combination of chromic acid and sulfuric acid medium corrosion, oxidation resistance and salts such as Fe, ",,, Cu "or with other antioxidant corrosion, such as higher than normal temperature hypochlorite solution, the corrosion of the water

titanium

The sea, all kinds of chloride and hypochlorite, oxidizing acid (including fuming sulfuric acid), organic acid, alkali corrosion.Not a pure resistance reducing acid such as sulfuric acid, hydrochloric acid corrosion, but contains antioxidants such as acid (such as nitric acid, Fc++, Cu++), the corrosion is greatly reduced.

tantalum

It has excellent corrosion resistance and glass is similar.Besides fuming sulfuric acid, alkali, cut almost ability - chemical medium (including the boiling point of hydrochloric acid, nitric acid and sulfuric acid l below 50 ℃) of the corrosion.In the alkali diao;Corrosion resistant.

Platinum/titanium alloy

Almost can cut - chemical medium, but does not apply to aqua regia and ammonium salt.

Stainless steel coated with tungsten carbide

Used for non-corrosive, strong wear medium.

Note: due to the variety of medium, the corrosion resistance and affected by complex factors such as temperature, concentration, flow velocity and change, so the data in this table is for reference only.Users should choose according to actual situation, should be done when it is necessary to choose the corrosion test of material, such as coupon test.

13, correct selection:

Instrument selection is very important work in instrumentation, relevant data show that the instrument in two-thirds of faults in the practical application is instrument error caused by selection or wrong installation, please pay special attention to.

1, collect data:

By measurement of body composition;
Large flow, small flow;
Z high work pressure;
, z z high temperature low temperature;

2, range scope confirmation:

General industrial use measured medium velocity of electromagnetic flowmeter with 2 ~ 4 m/s advisable, under special circumstances, z low velocity should not be less than 0.2 m/s, high z should be not more than 8 m/s.If the medium containing solid particles, commonly used flow rate should be less than 3 m/s, prevent excessive friction lining and electrode;For viscous flow, the velocity can choose more than 2 m/s, larger velocity help eliminate electrode automatic on the effect of viscous material, to improve accuracy of measurement.

Under the condition of the range of Q have been identified, according to the velocity V can be decided to the size of the flow meter diameter D, the range of the values calculated by the next type:

Q = PI D2V / 4
Q: flow (㎡ / h) D: pipe diameter V: velocity (m/h)

Electromagnetic flow meter range of Q z flow value should be greater than expected, the flow of the normal value in a full scale slightly greater than the flowmeter calibration 50 is advisable.

3And the reference flow range:

CAL(mm)

Flow range(m3/h)

CAL(mm)

Flow range(m3/h)

Phi is 15

0.06 ~ 6.36

Phi 450

57.23~5722.65

Phi 20

0.11~11.3

Phi 500

70.65~7065.00

Phi is 25

0.18~17.66

Phi 600

101.74~10173.6

Phi 40

0.45~45.22

Phi 700

138.47~13847.4

Phi 50

0.71~70.65

Phi 800

180.86~18086.4

Phi 65

1.19~119.4

Phi 900

228.91~22890.6

Phi 80

1.81~180.86

Phi 1000

406.94~40694.4

Phi 100

2.83~282.60

Phi 1200

553.90~55389.6

Phi 150

6.36~635.85

Phi 1600

723.46~72345.6

Phi 200

11.3~1130.4

Phi 1800

915.62~91562.4

Phi 250

17.66~176.25.

Phi 2000

1130.4~113040.00

Phi 300

25.43~2543.40

Phi 2200

1367.78~136778.4

Phi 350

34.62~3461.85

Phi 2400

1627.78~162777.6

Phi 400

45.22~4521.6

Phi 2600

1910.38~191037.6

14, selection of coding:

specifications

Pipe size

Wei measurement and control of the () material: nodular cast iron and stainless steel

ZW-LDE

15-2600

Code name

Electrode materials

K1

316L

K2

HB

K3

HC

K4

titanium

K5

tantalum

K6

Platinum alloy

K7

Stainless steel coating

Coated tungsten carbide

Code name

Lining material

C1

teflonF4

C2

fepF46

C3

Poly fluoro ethyleneFS

C4

Poly (butyl rubber

C5

Polyurethane rubber

Code name

function

E1

0.3level

E2

0.5level

E3

1level

F1

4-20Madc,load750 or less Ω

F2

0-3khz,5vActive, variable pulse width, the output high frequency effectively

F3

RS485interface

T1

The normal temperature type

T2

High temperature type

T3

Ultra high temperature type

P1

1.0MPa

P2

1.6MPa

P3

4.0MPa

P4

16MPa

D1

220VAC±10%

D2

24VDC±10%

D3

Lithium battery type

J1

A body structure

J2

Points body structure

J3

Explosion-proof one body structure

15, design selection and ordering information:

1, the measured medium: name, composition, status, electrical conductivity and electrical conductivity;

2, working temperature (℃);

3, work pressure (Mpa);

4, the pipe diameter (DN), the smallest, normal, scope of quantity (m3 / h);

5, corrosion resistance, wear resistance, whether there is a negative pressure;

6, installation requirements and the environment: a body or fission, signal output, communications, power supply;

7, installation environment: protection grade and explosion-proof requirements.

After-sales service commitment:

1, from the date of signing of the contract, I in the way provided for products of the company offers free maintenance and maintenance service, commitment to lifelong maintenance service;

2, jiangsu wei measurement and control instrument co., LTD. Sales manager will be in regular contact with customers, understand the usage of products, and solve the problems of the customers to use in the process of produce, free of charge to provide technical support;

3 the man-made damage is found, the warranty period, our company is responsible for the maintenance, and the resulting maintenance fee;

4, product quality problems or are not satisfied with product, the user can choose unconditional return, wei tt&c don't charge any fees, appear quality problem, bear the freight back and forth.


Browse:
Return To The Top

分享到: