Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

Battery liquid turbine flow meter

6液體渦輪流量計(電池供電).png
  • 6液體渦輪流量計(電池供電).png
ZW - LWGY seriesBattery liquid turbine flow meterIs advanced ultra low power single chip microcomput…

Description:

ZW - LWGY seriesBattery liquid turbine flow meterIs advanced ultra low power single chip microcomputer technology of turbine flow sensor and display integration of integrating new intelligent instrument, adopts double row at the scene of the liquid crystal display, with compact bodies, intuitive and clear reading, high reliability, without external power supply interference, lightning resistance, low cost, obvious advantages.Instrument instrument correction coefficient of three, nonlinear intelligent compensation coefficient, and on-site correction.High-definition LCD display (four significant figures) instantaneous flow and cumulative flow (eight significant figures, with reset function).All valid data after 10 years is not lost when power supply drop.This kind of turbine flowmeter are explosion-proof products, explosion-proof level for: ExdIIBT6.
The turbine meter according to the power supply mode, have far eastone signal output can be divided into LWGY - a/B and LWGY - - C.
LWGY - - B: power supply using 3.2 V10AH lithium batteries (can run continuously for 4 years);No signal output function.
LWGY - / C: 24 VDC power supply, power supply adopts two wire output standard 4-20 ma current signal, and can need according to different site, can increase the RS485 or the HART communication.
Second, the working principle: 
ZW - LWGY series battery liquid working principle of turbine flowmeter is a fluid flowing through the sensor shell, because of the impeller blade and flow to a certain Angle, the fluid force makes the blade with rotational torque, to overcome the friction torque and fluid resistance, blade rotation speed stability after the moment balance, under certain conditions, the speed is proportional to the velocity of flow, because there are magnetic conductivity blade, it is in the signal detector (composed of * magnetic steel and coil) magnetic field, rotating blade cutting lines, periodically changing coil magnetic flux, so that the coil ends of inductive electric pulse signal, the signal after amplifier amplification plastic, form a certain amplitude of continuous rectangular pulse wave, can be spread far to display instrument, show the instantaneous flow and cumulative amount of the fluid.Within the scope of a certain flow, pulse frequency f and flows through the sensor of fluid is proportional to the instantaneous flow rate Q, flow equation is: Q = 3600 x f/k;Type: 
F - pulse frequency (Hz); 
K - the instrument coefficient of sensor 1 / m3, given by the check list.If [1 / L] as the unit 
Q - fluid transient flow (working conditions) (m3 / h), 
3600 - conversion factor. 
Coefficient of each sensor of the instrument in the calibration certificate will be completed by the manufacturer, set into the display instrument of form a complete set of k value, can show the instantaneous flow and cumulative total. 
Applications:
ZW - LWGY series battery liquid turbine flowmeter is widely used in petroleum, chemical industry, metallurgy, water supply, paper making, environmental protection, food and other fields, and is suitable for the measurement in a closed pipe and stainless steel and corrode fused alumina, tungsten carbide, and no fiber, particle impurities such as liquid.If with display instrument with special functions, can automatically quantitative control, such as excessive alarm purposes. 
Four, the main features: 
1, sensor is cemented carbide bearing thrust type, not only guarantee the accuracy, and improve the wear resistance. 
2, simple structure, strong and tear open outfit is convenient. 
3, wide measuring range, low threshold velocity. 
4, small pressure loss, good repeatability, high precision. 
5, have a high resistance to electromagnetic interference and vibration resistance. 
Five, the technical parameters: 
Meter diameter: threaded connections: 4, 6, 10, 15, 20, 25, 32, 40; 
Flange connection: (15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200; 
Insert: more than 200; 
Range scale: 1:10;1:15.1; 
Instrument material: stainless steel 304, 316 (L) stainless steel, etc; 
Medium temperature: - 20 ℃ ~ + 120 ℃; 
Ambient temperature: - 10 ℃ ~ + 55 ℃; 
Relative humidity: 5% ~ 9%; 
The atmospheric pressure: 86 ~ 106 kpa; 
Power supply: the scene display type: instrument with lithium batteries; 
Explosion-proof forms: basic not explosion-proof, explosion-proof type; 
Protection grade: IP65, IP67. 
Six, instrument type:
A, the scene display type:
The intelligent flowmeter is the use of advanced single chip microcomputer technology design of the new display instrument of the flow meter, and the flow sensor of pulse signal output (such as turbine, vortex.).It can display instantaneous flow and cumulative amount.Cumulative flow: eight digit, decimal point three significant figures.Instantaneous flow: six figures, but showed a litre.Display precision: plus or minus a display unit.Signal output: pulse output: 1 ~ 3000 hz for + 12 ~ + 24 VDC power supply output current: 4 ~ 20 ma away for + 24 VDC power supply (two wire system) built-in 2 section 3 v lithium battery power supply in parallel.When the voltage is lower than 2.7 V, the under-voltage directives flameproof.Small signal removal function.
B, pulse output type:
Working voltage: + + 12 VDC or 24 VDC two (customer order must be selected before a power supply).Signal transmission distance: less than 250 meters.Output signal, square wave signal amplitude: + 12 VDC power supply amplitude is about 10 v + 24 VDC power supply amplitude of about 20 v: amplifier and turbine flow sensor connection for the M16 x 1.5 thread, after the turbine flow sensor installation, twist to the turbine flow sensor, the amplifier with the hand twist to sense amplifier and then take the lock nut.Connection: type pulse output amplifier foreign lead with three root, red, white line and shielding.Is the power supply line, white line for pulse output and display, or other equipment connection, shielding grounding
C, 4 ~ 20 ma output type:
Outside the working voltage: 24 VDC power supply + (two wire system) output signal: 4 ~ 20 ma, or 1, 4-5 v ma corresponding to zero flow turbine flow sensor, 20 ma for turbine flow sensor zui large flow, flow range turbine flow sensor nameplate.Signal transmission distance: less than 250 meters.After the installation of turbine flow sensor installation, twist the amplifier to the turbine flow sensor (m16 x 1.5 thread), joint hands after twist to the sense amplifier has exactly bring tight lock nut.Connection: 4 ~ 20 ma output type amplifier foreign fuses with the red and white line.The red line for the power cord, white line for line.
D, fission remote display type:
Outside power supply working voltage: 220 vac signal transmission distance: less than 250 meters display instantaneous four: accumulative total nine display display size: horizontal type: 160 mm x 80 mm upright: 80 mm x 160 mm display with 4 ~ 20 ma output and can be connected to the computer.
Seven, structure and installation method: 
1, instrument installation using thread connection and clamp type; 
2, liquid flow direction when installation should be direction of arrow and indicating flow sensor shell, and a straight pipe upstream should be 6 D, or downstream straight pipe should be 5 D or higher measured pipeline measured diameter (D). 
3, sensors should be far away from the external magnetic field, such as can't be avoided, necessary measures should be taken; 
4, in order to not affect the normal delivery of the liquid, maintenance should be straight section on opposite sides of the sensor installation outside the by-pass pipe; 
5, sensors, outdoor installation time, please prepare amplifier plug waterproof processing; 
6, sensor and display instrument connection, should according to the power of the amplifier to choose connection mode, as shown in the relevant specification. 
Eight, wiring and grounding considerations: 
Wiring matters needing attention 
1, using a full cable as soon as possible. 
2, should as far as possible away from electrical noise (such as power transformer, electric motor and the power cord), avoid parallel to the power the power cord wiring. 
3, Suggestions in the end of the thick wire adopts the tin welding clamping lugs. 
4, for the waterproof and mechanical damage, the cable into the metal tube inside, but may not have high power transmission cables, within the same catheter (a transmission cable transmission of zui power is greater than the flowmeter signal transmission cables zui small power 10 times, both cannot be installed on the same catheter). 
5, the existing strong magnetic field outside the area, should make the axis of the detection device with the outside world vertical or the direction of the magnetic flux of the magnetic field with high permeability material for shielding flow sensor or external magnetic source. 
6, explosion-proof type turbine flow sensor cable connection, must strictly abide by the relevant standards of explosion-proof amplifier. 
Grounding problem 
1, the shielding wire can only be grounded at one end, on display instrument grounding. 
2, reliable grounding should be good, explosion-proof type grounding resistance should be less than 10 Ω. 
The use of turbine flow time must pay attention to the points: 
1, requires clean measured medium, low viscosity, corrosion resistance is small, do not contain impurities, in order to reduce the wear of bearing.If the liquid to be measured a grudge or containing gas, the flowmeter before venting device.In order to avoid damage of impurity in the fluid into the transmitter devious, and in order to prevent turbine stuck, add filters when necessary. 
2, the installation of the flowmeter should avoid vibration, avoid magnetic field and thermal radiation. 
3, medium density and viscosity changes have an impact on flow value, should be revised if necessary.
Nine, turbine flowmeter installation site:
1, the installation site should comply with the environmental temperature at 25 ~ 55 ℃ scope, humidity < 80% RH;
2, well ventilated, avoid sun and rain;
3, avoid in piping vibration or the place of stress;
4, avoid easily affected by the strong thermal radiation and radioactive places;
5, must avoid the outside strong electromagnetic field disturbance to the detection signal.If unavoidable, should be set on the amplifier of the flowmeter (sensor) shield and other measures to eliminate interference;
6, in the places where requires explosion-proof, and isolation amplifier should be adopted;
7, the installation position should consider ease of installation, operation, maintenance.
Ten, use notice: 
Measured liquid 1, when using, should maintain clean, do not contain impurities such as fiber and particles. 
2, sensors, at the beginning of the use should be to slowly filled with liquid sensor, and then open the outlet valve (the valve should be installed in the back-end flow meters), it is strictly prohibited to sensors in liquid state under high velocity impact. 
The maintenance period of 3, sensors, generally for half a year.Maintenance when cleaning, please note that you are the measuring chamber of damaged parts, especially in the impeller.Please watch the orientation and the position of the impeller when assembling. 
4, sensors, need not when, should be clean inside the liquid, dry and after on both ends of the sensor and protective cover, prevent dirt to enter, and then placed in a dry place preservation.(this is very important) 
5, with the filter should be cleaned regularly, need not when should clean the internal liquid, like sensors, dustproof set, placed in a dry place preservation. 
6 transmission cables, the sensor can be raised or buried (buried iron pipe should be set. 
7, in front of the sensor installation, and the first display instrument or oscilloscope connected wires, power supply, with my mouth to blow or hand dial the impeller, make its rapid rotation observations have showed that sensor installation again when have shown.If no display, should check the relevant parts, troubleshooting.

Eleven, parameter table:

Instrument model

LWGY-N

LWGY-A

LWGY-B

LWGY-C

Signal output

pulse

4-20mA

There is no

4-20mA/pulse

Power supply

+24VDC

Plus or minus 15%

+24VDC

Plus or minus 15%

24VDC

Plus or minus 15%

24VDC

Plus or minus 15%

The lithium battery

24VDC

Plus or minus 15%

Precision grade

1.0~0.5level

1.0~0.5level

1.0~0.5level

Measuring range

The standard range

The standard range

Standard range or extension

display

There is no

There is no

There are

Communication interface

There is no

There is no

There is no

optionalRS485

Communication protocol

There is no

There is no

There is no

Moubus HART

Instrument material

Stainless steel

Stainless steel

Stainless steel

Explosion-proof grade

There is no

ExdIIBT6orExiaIICT4

ExdIIBT6orExiaIICT4

Protection grade

IP60

IP65

IP65

The machine power consumption

< 1W

< 1W

< 1W

Instrument drift diameter

DN4~DN250

DN4~DN250

DN4~DN250

Medium temperature

- 20℃ ~120

- 20℃ ~120

- 20℃ ~120

The environment temperature

- 30℃ ~60

- 30℃ ~60

- 30℃ ~60

Twelve, measurement range and working pressure:

Meter diameter(mm)

Normal flow range(m3/h)

Expand the flow range(m3/h)

Conventional resistance pressure(MPa)

Special stress levels(MPa)

(Flange connection way)

DN 4

0.04~0.25

0.04~0.4

6.3

12、1625

DN 6

0.1~0.6

0.06~0.6

6.3

12、1625

DN 10

0.2~1.2

0.15~1.5

6.3

12、16、25

DN 15

0.6~6

0.4~8

6.3、2.5 (The flange)

4.0、6.3、1216、25

DN 20

0.8~8

0.45~9

6.32.5 (The flange)

4.06.3、1216、25

DN 25

1~10

0.5~10

6.32.5 (The flange)

4.0、6.3、12、1625

DN 32

1.5~15

0.8~15

6.3、2.5 (The flange)

4.06.3、12、16、25

DN 40

2~20

1~20

6.3、2.5 (The flange)

4.0、6.3、12、16、25

DN 50

4~40

2~40

2.5

4.06.3、12、16、25

DN 65

7~70

4~70

2.5

4.0、6.3、12、1625

DN 80

10~100

5~100

2.5

4.0、6.3、12、16、25

DN 100

20~200

10~200

2.5

4.0、6.3、12、1625

DN 125

25~250

13~250

1.6

2.5、4.0

DN 150

30~300

15~300

1.6

2.54.0

DN 200

80~800

40~800

1.6

2.5、4.0

13, selection of coding:

type No.

said Ming wei tt&c) in (

ZW-LWGY

-

-

-

-

-

-

-

The male

According to

tong

diameter

4







4mm, the standard range0.04~0.25m3/h, wide range0.04~0.4m3/h

6

6mm, the standard range0.1~0.6m3/hAnd quantity of wheel is wide0.06~0.6m3/h

10

10mm, the standard range0.2~1.2m3/h, wide range0.15~1.5m3/h

15

15mm, the standard range0.6~6m3/hWide range of0.4~8m3/h

20

20mm, the standard range0.8~8m3/h, wide range0.4~8m3/h

25

25mm, the standard range1~10m3/h, wide range0.5~10m3/h

32

32mm, the standard range1.5~15m3/h, wide range0.8~15m3/h

40

40mm, the standard range2~20m3/h, wide range1~20m3/h

50

50mm, the standard range4~40m3/h, wide range2~40m3/h

65

65mm, the standard range7~70m3/h, wide range4~70m3/h

80

80mm, the standard range10~100m3/h, wide range5~100m3/h

100

100mm, the standard range20~200m3/h, wide range10~200m3/h

125

125mm, the standard range25~250m3/h, wide range13~250m3/h

150

150mm, the standard range30~300m3/h, wide range15~300m3/h

200

200mm, the standard range80~800m3/h, wide range40~800m3/h

type

N

The sensor type:+12Vor24VPower supply, signal pulse output three wire system

A

Transmitter type:+24VThe power supply, and two wire output4~20mA

B

Intelligent: lithium-ion batteries, the scene show no signal output

C

Intelligent:+24VPower supply, the scene display and output two wire4~20mA

C1

Intelligent:+24VDisplay with a power supply, the sceneRS486Communication protocol

C2

Intelligent:+24VDisplay with a power supply, the sceneHARTCommunication protocol

Precision grade

05

precision0.5level

10

precision1.0level

vortex wheel

class type

W

Wide-range turbine

S

Standard turbine

material mass

S

304Stainless steel

L

316(L)Stainless steel

explosion-proof

E

Explosion-proof type (Explosion-proof level:ExdBT6)

Classes.

N

conventional

H

High pressure

Note: DN15 ~ DN40 routine for the threaded connection, such as hope use flange connection, please add after the "nominal diameter," "(FL)"
For example: choose a flange connection type explosion-proof diesel type turbine flowmeter measurement, pipeline for DN40, site need to display and remote transmission current signal, the required accuracy of 0.5 on the Richter scale, 304 stainless steel material, instrument 16 mpa pressure measurement range for the standard range, the product model should be: ZW - LWGY - 40 (FL) / / 5 C/S/S/E/H16.

14, designing order selection guidelines:

1, instrument selection, as far as possible not to use the work flow in the lower limit value, so the meter diameter should be as small as possible, in order to obtain a larger flow rate and flow range.

2, the flowmeter should be used in the technical parameters of medium pressure and temperature range.Don't deliberately choose the high pressure level and ultra-high temperature instrument, should be selected according to the actual work pressure and temperature instruments, which had higher prices.

3, in the explosive dangerous location, should choose explosion-proof type flowmeter.

4, the lower limit of flowmeter flow depends on the operation condition of the medium density and kinematic viscosity, the maximum flow is generally not affected by medium pressure and temperature, so to determine the flow range as long as you determine the actual minimum flow can be available.Calculate the minimum flow rate, flow range check table to determine the appropriate diameter.

After-sales service commitment:

1, from the date of signing of the contract, I in the way provided for products of the company offers free maintenance and maintenance service, commitment to lifelong maintenance service;

2, jiangsu wei measurement and control instrument co., LTD. Sales manager will be in regular contact with customers, understand the usage of products, and solve the problems of the customers to use in the process of produce, free of charge to provide technical support;

3 the man-made damage is found, the warranty period, our company is responsible for the maintenance, and the resulting maintenance fee;

4, product quality problems or are not satisfied with product, the user can choose unconditional return, wei tt&c don't charge any fees, appear quality problem, bear the freight back and forth.


Browse: