亚洲精品一本知道高清乱码|日韩一区二区三区在线观看不卡|亚洲精品美女在线观看播放|久久一本精品久久久久99|亚洲 一区 精品 在线

Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

The remote type flowmeter

12遠傳型腰輪流量計.png
  • 12遠傳型腰輪流量計.png
ZW-LL series The remote type flowmeter (meter) is referred to as a volume flow measuring instrument,…

Description:

Productoverview:

ZW-LL series The remote type flowmeter (meter) is referred to as a volume flow measuring instrument, measuring part adopts stainless steel material, with strong corrosion resistance, can be used for the flow measurement of crude oil moisture corrosion or other corrosive media. This scene shows the cumulative flow and flow meter can be equipped with remote output interface, the other with the photoelectric converter output electric pulse signal or analog signal, matched with a flow meter for remote measurement, display and control.

The utility model is characterized in that a metering chamber in the meter casing, the metering chamber has a pair or two pairs of tangent waist wheel rotation. In the outside of the casing and the coaxial flowmeter both search round a set of transmission gears meshing with each other, they make a waist wheel can be linked with each other.

ZW-LL series remote type flowmeter in the structure, the outer legs and waist wheel flowmeter the inner wall of the shell surface can be composed of a certain volume of the "bucket" space. We called the measuring room". When the fluid flow through the flow meter in timing, the import and export of differential fluid pressure under the action of two. According to the positive direction of rotation of the waist wheel. The formation of a metering chamber enclosed by the waist wheel and the shell. The fluid metering chamber filled with a single volume of imports from the waist wheel is divided into continuous fluid.

Flow meter mainly by the metering chamber and sealing couplings and counter three parts. Widely used in petroleum, chemical, electric power, metallurgy, transportation, food processing, medicine, defense, trade and other departments accurate measurement of oil and oil products, chemical solution and other fluid.

Two, work principle:

ZW-LL series remote type flowmeter is measured when the fluid flows through the metering chamber, in the import and export of the formation of differential pressure flowmeter, this pressure waist wheel driven by rotation. At the same time through fixed at the waist on the axle of the driving gear, the two round of continuous rotation of the waist. With the rotation of the waist wheel, the metering chamber is discharged continuously through the liquid flowmeter. The amount of each liquid flow through the metering chamber volume is four times, the sealing mechanism through the coupling, reducer, reducer rotating number is transferred to the counter, the counter is indicating liquid instantaneous flow and cumulative flow. Install the transmitter in the counter mechanism that the sender of the waist belt. With the display meter or computer system can realize remote (quantitative, cumulative and instantaneous automatic measurement and control function). Use display instrument Classification Manual see.

Three, application of measurement:

ZW-LL, can be used for pure crude oil, heavy oil flow measurement of high viscosity liquid;

ZW-LL-D can be used to prevent sand sand flow measurement of crude oil, heavy oil and other high viscosity fluid;

ZW-LL-F stainless steel is the contact with the medium flow meter stainless steel material manufacturing, has strong corrosion resistance, can be used for flow measurement of corrosive liquid, especially for the chemical industry;

ZW-LY-C light oil type is especially suitable for light oil, diesel oil flow measurement of low viscosity fluid.

Four, main features:

1, high measurement accuracy, the basic error is generally up to plus or minus 0.2% to plus or minus 0.5%, special requirements up to plus or minus 0.1%, flow characteristics generally not affected by the flow state, nor by the Reynolds number size limit.

2, can be used for high viscosity liquid flow measurement

The range of 3, the measuring accuracy is wide, the typical flow range of 5:1 to 10:1

4, the cumulative amount of fluid type wheel counter, without external energy, the use of instant noodles counter cumulative flow double display, one of which can be reset to zero, the convenience of users in the case of continuous measurement.

5, measuring between components without contact, no wear, long service life.

6, large caliber flowmeter and the rotor, reduce running noise and vibration meter.

Fifth, technical parameters:

1, allow the basic error: + 0.1%, 0.2% + +, 0.5%;

2, nominal diameter DN (mm): 15 ~ 300;

3, nominal pressure PN (M.Pa): cast iron, stainless steel (A) (P) 1, 1.6, 2.5, 4, 6.3; 2.5, 4 cast steel (E), 6.3, 9.6;

4, the measured liquid temperature:

A. low temperature: -40 ~ +60 c;

B. at room temperature -10 to +80 DEG c;

The temperature of C. -10 to +200 DEG c;

D. high temperature -10 to +300 DEG c;

5, the measured liquid viscosity (mPa.s): 0.3 ~ 50000;

6, pipe connection: GB/T9118-2000 (Chinese; NIST (American Standard) standard); BSPT (BSP): NPT (American pipe thread);

7, on-site display: 99999999 L (cumulative flow) of 9999999.9 L (single flow); 9999999.9 L (transient flow);

8, output signals: pulse signal, 4 ~ 20mA, 4 ~ 1-5V, 20mA +HART, MODBUS RS232, RS485 protocol support communication (Ren Xuan);

9, explosion-proof grade: EXiaIIBT5EXiaIICT5 protection grade: IP65.

Six, installation and use:

1, flow meter should be installed before the filter, the meter with the direction of arrow.

2, when the measured liquid containing gas, flow meter should be installed before the gas separator.

3, whether the pipeline is vertical or horizontal installation, but the waist wheel flowmeter installation into a horizontal position (i.e. dial should be perpendicular to the ground).

4, the correct installation of flowmeter in the case, if it is not easy to see the readings, the counter rotating 180 degrees or 90 degrees can be.

5, the throttle valve should be installed in the meter inlet opening and closing valve is installed at the outlet, the use of open or close the valve to start slowly, do not suddenly open valve.

6, prohibited the use of steam flowmeter by line sweep.

7, in the continuous use of departments, need to add a bypass pipeline flowmeter.

Before the installation of 8, flow meter, pipeline flushing, flushing the pipe (alternative meter position) prevent the welding slag and other debris into the meter.

9, check the water meter is composed of cast iron, cast steel.

10, when using the size of the flow meter shall not exceed the technical requirements. The flowmeter work on Zui flow 70~80% was better.

11, if the measured liquid is corrosive, need to use stainless steel flowmeter, if corrosive, need to use 0Crl8Ni12MO2Ti material flow meter.

Seven, installation notes:

1, before installation shall not open the inlet flow, the outlet seal two;

2, when the pipe is installed on the device more, should be put on after the installation of flow meter;

3, where conditions permit, the pipeline must be high pressure purge before installation;

4, installed at the interface with an iron pin, careful removal of burr;

In front of the 5 meter must be installed, filter, filter media measurement; measurement of liquid, if containing gas, optional getter device flowmeter, ensure the measuring precision of flowmeter;

6, installation modes, horizontal vertical installation can be installed vertically progress under the lower upper is not affected, but the meter shall not be reversed, anti loaded, opposite directions, waist wheel reversal, because the rotation between different gap design will damage the waist wheel;

7, on the lower straight pipe section, but must set aside to install filtering device enough distance;

8, waist wheel rotation is by fluid pressure as the driving force, viscous medium when the measurement is too high, affect the measuring precision of flowmeter;

To avoid the above points, the measurement precision can achieve better flowmeter.

Eight, technical performance:

project

Model

Nominal diameter (mm)

Nominal pressure

(Mpa)

The measured liquid temperature (c)

Flow range (M? /h)

% accuracy

The installation form

Z small flow

Z flow

ZW-LL-8

Eight

0~1.6

0~2.5

0~4.0

0~6.4


Zero point two five

Two point five

Zero point two

Zero point five

Horizontal and vertical

ZW-LL-15

Fifteen


Zero point two five

Two point five

Zero point two

Zero point five

Horizontal and vertical

ZW-LY-20

Twenty

-20~+60

Zero point two five

Two point five

Zero point two

Zero point five

Horizontal and vertical

ZW-LL-25

Twenty-five


Zero point six

Six

Zero point two

Zero point five

Horizontal and vertical

ZW-LL-40

Forty


One point six

Sixteen

Zero point two

Zero point five

Horizontal and vertical

ZW-LL-50

Fifty

-20~+120

Two point five

Twenty-five

Zero point two

Zero point five

Horizontal and vertical

ZW-LL-80

Eighty


Six

Sixty

Zero point two

Zero point five

Horizontal and vertical

ZW-LL-100

One hundred


Ten

One hundred

Zero point two

Zero point five

Horizontal and vertical

ZW-LL-150

One hundred and fifty

-20~+350

Twenty-five

Two hundred and fifty

Zero point two

Zero point five

Horizontal and vertical

ZW-LL-200

Two hundred


Forty

Four hundred

Zero point two

Zero point five

Horizontal and vertical

ZW-LL-250

Two hundred and fifty

A heat sink

Sixty

Six hundred

Zero point two

Zero point five

Horizontal and vertical

ZW-LL-300

Three hundred


One hundred

One thousand

Zero point two

Zero point five

Horizontal and vertical

Pressure loss: the measured liquid viscosity is less than 30mpa.s, the pressure loss is less than 0.05Mpa.

Nine, appearance and installation size:

Table 1, cast iron type size:

Model

L

H

I

B

D

D1

N-D

ZW-LL15.06

One hundred and sixty

Two hundred and thirty-eight

Fifty-two

100*100

G11/4



ZW-LL20.06

One hundred and sixty

Two hundred and thirty-eight

Fifty-two

100*100

Ninety

Sixty-five


ZW-LL25.06

One hundred and eighty

Two hundred and sixty

Sixty-eight

120*120

G1/



ZW-LL40.1

Two hundred and forty

Two hundred and ninety

Eighty-eight

One hundred and seventy

One hundred and fifty

One hundred and ten

4-17.52

ZW-LL50.1

Two hundred and sixty-five

Three hundred and five

Ninety-seven

One hundred and ninety

One hundred and sixty-five

One hundred and twenty-five

4-C17.52

ZW-LL80.1

Two hundred and sixty-five

Three hundred and forty

One hundred and twenty-two

Two hundred and forty-six

Two hundred

One hundred and sixty

8-17.52

ZW-LL80II.1

Two hundred and sixty-five

Four hundred and seventy

One hundred and sixty-four

Two hundred and forty-six

Two hundred

One hundred and sixty

8-18

ZW-LL100.1

Five hundred and fifteen

Four hundred and twenty-five

One hundred and sixty-four

Three hundred and five

Two hundred and twenty

One hundred and eighty

8-18

ZW-LL150.1

Five hundred and sixty

Five hundred and fifty

Two hundred and twenty-five

Four hundred and fifty-five

Two hundred and eighty-five

Two hundred and forty

  8-22

Table 2, casting dimension:

Model

L

H

I

B

D

D1

N-D

ZW-LL25.3

One hundred and eighty

Two hundred and sixty

Sixty-eight

120*120

G11/4



ZW-LL40.4

Three hundred

Two hundred and ninety

Eighty-eight

One hundred and seventy

One hundred and fifty

One hundred and ten

4-18

ZW-LL50.4

Three hundred and sixty

Three hundred and fifteen

One hundred and three

Two hundred and seventy-six

One hundred and sixty-five

One hundred and twenty-five

4-18

ZW-LL80.4

Three hundred and sixty

Three hundred and forty-eight

One hundred and twenty-eight

Two hundred and fifty-four

Two hundred

One hundred and sixty

4-18

ZW-LL100.3

Five hundred and forty

Four hundred and thirty-five

One hundred and seventy-four

Three hundred and thirty

Two hundred and thirty-five

One hundred and ninety

4-22

ZW-LL150.3

Five hundred and sixty

Five hundred and fifty-two

Two hundred and twenty-seven

Four hundred and fifty-five

Three hundred

Two hundred and fifty

  4-26

Cast aluminum shape and dimensions of the same type of cast iron. 
Ten, flow range: ( M3/h ):

Nominal diameter 

Mm

Liquid viscosity

Three ~150mPa.s

Liquid viscosity

Zero point six ~3.0mPa.s

Liquid viscosity

Three ~ 150mPa.s

Liquid viscosity

Zero point six ~3.0mPa.s

ZW-LL15

Zero point two five ~ Two point eight

Zero point five ~Two point eight

Zero point five ~Two point eight

Zero point eight three~ Two point eight

ZW-LL20

Zero point two five ~ Two point eight

Zero point five ~Two point eight

Zero point five ~Two point eight

Zero point eight three~ Two point eight

ZW-LL25

Zero point six ~Six point eight

One point two ~Six point eight

One point two ~ Six point eight

Two ~ Six point eight

ZW-LL40

One point six ~Eighteen

Three point two ~Eighteen

Three point two ~Eighteen

Five point three ~Eighteen

ZW-LL50

Two point five ~Twenty-eight

Five ~ Twenty-eight

Five ~ Twenty-eight

Eight point three ~Twenty-eight

ZW-LL80

Six ~ Sixty

Twelve ~ Sixty

Twelve ~ Sixty

Twenty ~ Sixty

ZW-LL80A

Twelve ~ One hundred

Twenty-two ~One hundred

Twenty ~ One hundred

Thirty-three point three ~ One hundred

ZW-LL100

Ten ~ One hundred

Twenty ~ One hundred

Twenty ~ One hundred

Thirty-three point three ~ One hundred

ZW-LL150

Forty ~ Two hundred

Forty ~ Two hundred

Forty ~ Two hundred

Sixty-six point seven~ Two hundred

ZW-LL200

Eighty ~ Three hundred and sixty

One hundred and twenty ~ Three hundred and sixty

Thirty-six ~ Three hundred and sixty

Fifty ~ Three hundred and sixty

ZW-LL250

Eighty ~ Five hundred and forty

One hundred and twenty ~ Six hundred

Fifty ~ Five hundred and forty

One hundred ~ Six hundred

ZW-LL300

One hundred and fifty ~ Eight hundred

Two hundred ~One thousand

One hundred and forty ~ Eight hundred

Two hundred ~ One thousand

Precision grade

Zero point five level

Zero point two level 


Browse:
Return To The Top

分享到: