ZW-LZB/LZJ series Glass tube rotameter According to its purpose and scope can be divided into: ordin…
Description:
Productoverview:
ZW-LZB/LZJ seriesGlass tube rotameterAccording to its purpose and scope can be divided into: ordinary type, ribbed vascular type, small flow and low profile type, corrosion type, laboratory type, insulation type, alarm type and high pressure type eight series.According to the formulation of national instrument series, regardless of which Zui series, ranging from 1 to 100 mm in diameter and a total of 12 numbers, can measure the flow range: liquid (water) 0.1 ml / min to 40 cubic meters / hour, gas (air) 1 ml / min to 1000 cubic meters / hour.For environmental protection equipment of the glass rotameter is generally not more than 10 mm diameter, the flow measurement of small flow range.
Two, work principle:
ZW-LZB/LZJ series of glass tube rotameter is mainly composed of a bottom enlarged glass tube and a cone with the magnitude of fluid flow moves up and down the stainless steel float.The fluid flows through the cone bottom tube, buoyancy A fluid kinetic energy generated on the float lift S and fluid to float up, when the lift and buoyancy of A and S is equal to the gravity float G, float in the balance, stable at a certain height position, cone scale on the tube indicates that the fluid flow value.
ZW-LZB- (F) for smooth wall cone tube flowmeter tube diameter meter above DN15, the float remained stable through the movement, the guide rod; ZW-LZJ- (F) three meter cone tube guide rib, the float remained stable.Through the meter diameter of DN10 or less connected by a hose, equipped with needle flow control valve; path DN15 flowmeter with flange connection.
Three, application:
ZW-LZB/LZJ series of glass tube rotameter is mainly used in chemical, petroleum, light industry, medicine, chemical fertilizer, chemical, food, dyestuff, environmental protection and scientific research departments, used to measure single-phase non pulsating (liquid or gas) fluid flow.
Anticorrosion type is mainly used for the detection of corrosive liquid and gas medium flow, such as acid and alkali, oxidant, strong oxidizing acid, organic solvents and other corrosive gas or liquid medium flow detection.
Four, main features:
1, small pressure loss.In the process of using, can be fully utilized, without a lot of effort too much, all the pressure can be fully used, there will be no loss.
2, reliable performance.Glass rotor flowmeter in operation, frequent failure will not ensure good operation.When people are in the process of using, don't worry about running for it.Good performance, high reliability, can be assured use.
3, simple structure, convenient installation and use.The structure of the glass rotameter is simple, the installation is very convenient, can be installed in a short period of time.
Fifth, technical parameters:
1, size: DN2 ~ 100mm;
2, measuring range: water (20 C): 1L/h ~ 100m3/h, gas (101325Pa, 20 C): 16L/h ~ 3000m3/h;
6, working temperature: less than or equal to 120 DEG c;
7, connection: hose, metal pipe, flange (GB/T9119-2000);
8, material: flange, float, a guide rod, a supporting plate and bolts are made of stainless steel 304 (1Cr18Ni9Ti), type LZB-B.
Note: the wetted materials for use in 316, is a model for the LZB-Bo, can be customized.
For stainless steel PTFE is type LZB-BF (or BoF), can be customized.
Six, selection method:
1, measurement.Measuring the media type, size, pressure and chemical properties.Such as liquid and gas medium, the corrosive medium should choose corrosion resistance meter.
2, the performance of flowmeter.The above conditions are identified in general, if the price is no big change, may be preferred needle valve is arranged on the upper part of the large circulation flow meter; hole, direct flow scale; simple structure; small exterior dimensions etc..Such as small flow range, you can choose to use the ball float type, because of its measurement stability, not easy dust, high precision, good interchangeability.
The price of 3, according to the.Generally speaking, the high price of high precision.According to the measurement instruments such as precision grade, only through the medium of control measure, the operation adjustment, after always stabilize the throughput, so the accuracy is minor.
Seven, matters needing attention:
1, don't put the front cover removed, because the glass tube easy blasting, shell to protect.
2, when used in winter, should pay attention to keep warm, if the night is not used, the residual liquid in the flow discharged, so as not to freeze broken glass tube.
3, to the pipeline installation, first look at the downstream pipeline is in a straight line.If not in a straight line, will not only affect the measuring accuracy of the instrument, but also will damage the flowmeter.
4, when the valve is opened, will slowly open, if the estimated flow to floating rotor, and the rotor does not move up, immediately stop valve, tap the pipeline, so that the rotor can slowly rise.
5, first observed within the flow tube is intact, glass tube is easy to damage; second is to remove the rotor fixture, gently slide backward to see whether the rotor freely up and down.If not free to slide, vibration plate gently.If we can not slide, would need professional solutions.
Eight, specifications and measuring range:
1, ordinary type:
LZB-2
LZB-3
Model
LZB-4
LZB-6
LZB-10
Phi 2
Phi 3
Nominal diameter mm
Phi 4
Phi 6
Phi 10
Less than or equal to 1
Less than or equal to 1
The working pressure of MPa
Less than or equal to 1
Less than or equal to 1
Less than or equal to 1
+ 4
+ 4
Basic error limit%
+ 4
+ 2.5
+ 2.5
1:10
1:10
The scope of
1:10
1:10
1:10
0.4~4
2.5~25
liquid Ml/min
measuring range
liquid L/h
1~10
2.5~25
6~60
0.6~6
4~40
1.6~16
4~40
10~100
1~10
6~60
2.5~25
6~60
16~160
1.6~16
10~100
6~60
40~400
Gas Ml/min
Gas L/h
16~160
40~400
100~1000
10~100
60~600
16~160
100~1000
25~250
60~600
160~1600
25~250
160~1600
40~400
100~1000
250~2500
2, ordinary type:
Model
LZB-15
LZB-25
LZB-40
LZB-50
LZB-80
LZB-100
Nominal diameter
Phi 15
Phi 25
Phi 40
Phi 50
Phi 80
Phi 100
Ratio measurement
1:10
1:10
1:10
1:10
1:5 1:10
1:5
Working pressure
Less than or equal to 0.6
Less than or equal to 0.6
Less than or equal to 0.6
Less than or equal to 0.6
Less than 0.4
Less than 0.4
Precision grade
Two point five
One point five
One point five
One point five
One point five
One point five
Flow range
liquid
(m3/h)
16-160 (L/h)
40-400 (L/h)
0.16-1.6
0.4-4.0
1-10
5-25
25-250 (L/h)
60-600 (L/h)
0.25-2.5
0.6-6.0
1.6-16
8-40
40-400 (L/h)
100-1000 (L/h)
Gas
(NM3/h)
0.25-2.5
1-10
4-40
10-100
50-250
120-600
0.4-4.0
1.6-16
6-66
16-160
80-400
200-1000
0.6-6.0
2.5-25
3, corrosion resistance:
Model
LZB-15F
LZB-25F
LZB-40F
LZB-50F
LZB-80F
LZB-100F
Nominal diameter
Phi 15
Phi 25
Phi 40
Phi 50
Phi 80
Phi 100
Ratio measurement
1:10
1:10
1:10
1:10
1:5 1:10
1:5
Working pressure
Less than or equal to 0.6
Less than or equal to 0.6
Less than or equal to 0.6
Less than or equal to 0.4
Less than or equal to 0.4
Less than or equal to 0.4
Precision grade
Four
Two point five
Two point five
Two point five
Two point five
Two point five
Flow range
liquid
(m3/h)
16-160 (L/h)
40-400 (L/h)
0.16-1.6
0.4-4.0
1-10
5-25
25-250 (L/h)
60-600 (L/h)
0.25-2.5
0.6-6.0
1.6-16
8-40
40-400 (L/h)
100-1000 (L/h)
Gas
(NM3/h)
0.25-2.5
1-10
4.0-40
10-100
50-250
120-600
0.4-4.0
1.6-16
6.0-66
16-160
80-400
200-1000
0.6-6.0
2.5-25
4, LZB-S:
Model
LZB-15S
LZB-25S
LZB-50S
LZB-80S
Nominal diameter mm
Phi 15
Phi 25
Phi 50
Phi 80
The working pressure of MPa
Less than or equal to 0.6
Less than or equal to 0.6
Less than or equal to 0.6
Less than 0.4
The basic error indication limit%
+ 2.5
+ 2.5
+ 2.5
+ 2.5
measuring range
Liquid L/h
4~90
70~700
450~7000
7000~30000
Stainless steel Flanges, a float, a guide rod, a supporting plate and bolts are made of stainless steel 304 (1Cr18Ni9Ti), type ZW-LZB- (B). Wetted materials such as the need to use 316, then type ZW-LZB- (Bo), can be customized. For stainless steel PTFE is type ZW-LZB- (BF) (or BoF), can be customized. PTFE type Base, float, needle with polytetrafluoroethylene (PTTFE).Support plate and screws made of stainless steel.
Nine, appearance and installation dimensions:
Table 1,
Path
The size (mm)
A
B
C
D
E
Two
One hundred and ten
One hundred and thirty-two
One hundred and fifty
M8 * 1
31 x 26 (front)
Three
One hundred and ten
One hundred and thirty-two
One hundred and fifty
M8 * 1
31 x 26 (front)
Four
One hundred and seventy
Two hundred and eight
Two hundred and thirty-eight
Phi 11
40 x 34 (front)
Six
One hundred and seventy
Two hundred and eight
Two hundred and thirty-eight
Phi 11
40 x 34 (front)
Ten
One hundred and seventy
Two hundred and eight
Two hundred and thirty-eight
Phi 11
40 x 34 (front)
Table two:
Diameter (mm)
The size (mm)
A
B
C
D
E
Fifteen
Phi 95
Phi 65
Four hundred and seventy
Phi 15
With the diameter of 14 4-
Twenty-five
Phi 105
Phi 78
Four hundred and seventy
Phi 25
With the diameter of 14 4-
Forty
Phi 145
Phi 110
Five hundred and seventy
Phi 40
With the diameter of 18 4-
Fifty
Phi 160
Phi 125
Five hundred and seventy
Phi 50
With the diameter of 18 4-
Eighty
Phi 185
Phi 150
Six hundred and sixty
Phi 80
With the diameter of 18 4-
One hundred
Phi 205
Phi 170
Six hundred and sixty
Phi 100
With the diameter of 18 4-
10, encoding selection:
ZW-LZB
-
caliber
function
Description (Zhongwei control)
DN2-100
caliber
No label
Ordinary type
F
Corrosion proof type, PTFE base (for DN2~DN10) or carbon steel flange lining PTFE
B
All stainless steel material: 304 stainless steel
B0
All stainless steel material: 316 stainless steel
F/B (B0)
Type: stainless steel corrosion-resistant stainless steel flange (304 or 316) lined with PTFE (for DN15~DN100)
ZW-LZB
-
.
.
Glass tube flowmeter
Common type: mainly applicable to non corrosive medium measurement;
Corrosion proof type: mainly suitable for corrosive medium measurement;
All stainless steel type: mainly applicable to sanitary and weak corrosive medium measurement, can anti corrosive gas environment for use in;
Stainless steel corrosion proof type: mainly suitable for corrosive media measurement, can anti corrosive gas environment in use.
Eleven, ordering:
1, according to the measurement of the fluid is a gas or liquid, the correct selection of ZW-LZB rotor flowmeter.
2, the measured fluid is non corrosive with ordinary type, corrosive resistant type selection.
3, please specify when ordering the names, the measured flow rate, pipe diameter and pressure, temperature, density, viscosity, etc..According to the user's density of correction, making special flow gauge.
4, according to the measurement range and measured fluid applications such as choosing the suitable type of the specifications.As the special requirements of the flowmeter, or call the sales department, and company.
Customer service service commitment:
1, our series of flowmeter series product quality problems within 12 months, responsible for free maintenance.
2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
4, the warranty period after the product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.