Side mounted remote magnetic flip plate level gauge

17側(cè)裝遠(yuǎn)傳磁翻板液位計(jì)01.jpg
  • 17側(cè)裝遠(yuǎn)傳磁翻板液位計(jì)01.jpg
The side mounted remote magnetic flip-flop level gauge has very high sensitivity and wide field of v…

Description:

Productoverview:

ZW-UHZ-52A series The remote side mounted magnetic level gauge Made of stainless steel, suitable for all kinds of tower and tank spherical medium level measuring device and boiler equipment etc.. The whole process of measuring high sealing and anti leakage, no blind spots, striking display, intuitive readings, and large range of measurement. The first with the limit switch, can achieve the level of upper and lower limit alarm and control. Matching the level transmitter, the liquid level can be converted into a standard signal 4-20mADC signal, realize remote detection, indication, record and control.

Two, work principle:

1, the basic type

ZW-UHZ-52A series <strong> side mounted remote magnetic level gauge</strong> according to the principle of buoyancy and magnetic coupling developed. When measured in the container level lift, liquid level gauge leading tube float with lifting, the permanent magnets in float through the relay to the magnetic coupling indicator, drives a red and white turn column flip 180 degrees, when the liquid level rises, turn column turned from white to red, when the liquid level drops, by turning column red to white, red and white circles indicator at the actual height of the medium level in the container, so as to achieve the level of instruction.

2, limit switch output

The use of magnetic float with the liquid level gauge is installed in the mobile, the vertical tube set position switch, realize on-off control or alarm.

3, the electric remote

The magnetic level gauge transmitter installation. The sensor and transmitter converter is composed of two parts, the magnetic float moves up and down by the magnetic coupling of the measuring element in intraductal action, obtain the resistance signal changes, summoned into 0~10 or 4 ~ 20mA standard current signal output, and digital display connected to the instrument or computer, realize remote display and control.

Three, application:

ZW-UHZ-52A series <strong> side mounted remote magnetic level gauge</strong> is used for remote control of the liquid level measuring instrument, has the clear indication and remote control etc.. Can be widely used in petroleum, chemical, oil, medicine, food, wine and other industries in various types of liquid storage tank, storage tank, liquid storage tank, reaction tank, fermentation tank, liquid oil, liquefied gas, liquid hydrogen, liquid alkali, strong acid, weak acid, power plant boiler drum level, deaerator, drain tank high pressure heater, water tank, condenser, evaporator with other main pressure vessel with 1Cr8NitTi and 304+PTEE (PTFE), 316L, PVC, PP compatible liquid medium level liquid, and two kinds of medium interface measurement and display.

Four, main features:

1, simple design, compact, reliable, long service life, no maintenance can be installed for a long time in outdoor use;

2, the measuring tube and the liquid level display part, liquid level transmitter, alarm switch, air pressure is in complete isolation;

3, working pressure range is wide, the pressure from vacuum to 42MPa;

4, wide working temperature range, suitable for -160-450 from c;

5, widely used for liquid level measurement strength corrosive, inflammable and explosive, toxic, radioactive, strong agitation, dirty;

6, the model can be selected to achieve the level of Dingyou magnetic alarm switch, liquid level automatic control or alarm;

7, you can choose various types of 4-20mADC liquid level transmitter, realize remote centralized measurement and control.

Five, technical parameters:

1, measurement range: 150-6000mm (more than 6000mm orders can be negotiated);

2, accuracy: + 10mm;

3, medium density: 0.4-20g/cm3; medium density difference is not less than 0.15g/cm3;

4, working pressure: -0.1-42MPa;

5, working temperature: -160-450 degrees;

6, flange: flange diameter is DN20-DN150, the Ministry of chemical industry HG20592-97 standard flange flange standard, please specify when ordering the other flange standard users;

7, the environmental vibration frequency is less than or equal to 25HZ, the amplitude is less than 0.5mm;

8, flange material: carbon steel, 304, 316L;

9, follow the speed: less than 0.08m/s;

10, medium viscosity: less than 0.04Pa;

11, the leading tube material: 1Cr18Ni9Ti, 304, 316L, PP, PTEE, PTEE 304 stainless steel lining;

12, the leading tube diameter: 48, 57, Phi Phi Phi 62mm;

13, magnetic material is not higher than 80 DEG ABS = 80 DEG C: plastic, ceramic or metal;

14, the display is not higher than 80 DEG ABS: Material: plastic, more than 80 DEG C: Aluminum Alloy;

15, installation: vertical;

16, discharge valve: ball valve, needle valve.

Six, additional option:

1, the magnetic limit switch:

Open type: alarm with higher than;

Normally closed type: higher than the alarm off;

Switch capacity: 250VAC1A (resistive) 250VAC0.3A;

Switch life: 100000 times.

2, a liquid level transmitter:

Output current: 4-20mADC;

Resolution: + 1- + 10mm;

Load resistance: 500 ohms (24VDC power supply);

Transmission distance: 3000m;

Power supply: 16-30VDC.

3, intelligent liquid level transmitter:

Output current: 4-20ADC;

Resolution: 0.2mm;

Load resistance: 500 ohms (24VDC power supply);

Transmission distance: 3000m;

Power supply: 16-30VDC.

Seven, system components and wiring:

1, limit switch output:

A self holding function and reed switch converter, reed switches and converters were installed in the field and control room, by the converter to provide three pairs of contact switch.

2, the electric remote:

A measuring unit and a transmission unit is composed of two parts.

3, explosion-proof:

A with explosion-proof, upper and lower limit switch output:

Safety explosion-proof switch gate switch and relay contacts of the reed which can be directly provided to users of a normally closed or open contact. If the user needs to contact more special design orders.

With the explosion of the remote type security b:

Suitable for use in class II (Electrical Equipment Factory), C gas, the surface temperature of group T4 (135 C).

Note the use of c:

The shell is provided with external transmitter, users must be reliable grounding.

The use of the safety gate shall comply with the instructions for use of content.

The connecting cable transmitter and barrier for industrial safety end for two core shielded cable, wire cross-sectional area of more than 0.5m, cable distributed capacitance is 0.8 F.

Eight, use and maintenance:

Use:

1, auxiliary instrument and accessories with the specific content of the corresponding instrument and accessories see instructions.

2, to prevent a distance or move away in the process of float moves up and down in the main duct damage, lateral supporting special steel factory calibration gauge (with color logo) will hold the magnetic float. So after receiving the product or after installation, please remove the correction magnet, so that the float can move along with the liquid level, before use if the magnetic reversal of inconsistent color correction, available the magnetic suction along the instrument can work normally.

3, level meter installed, with magnetic correction of magnetic guidance once to zero below zero above display red, white display.

4, level gauge according to user needs with a heating jacket or an electric heating device, such as when ordering does not select this option, and in the installation of self used heat pipe, temperature and mixed with heat generated by the device can not exceed the rated temperature level meter.

5, level meter into travel, should open the valve on the liquid guide pipe, and then, the liquid valve open long, let the liquid medium smoothly into the main canal, avoid the liquid medium with a rapid rise caused by magnetic reversal failure or disturbed (in case of this phenomenon can be used to correct the magnet).

Maintain:

1, level gauge cylinder should be solid impurities and magnetic impurities, so as to avoid jamming and weaken the buoyancy of the float.

2, according to the media, the leading tube can be cleaned regularly, cleaning tube deposition of impurities.

3, clean or replace the float on the liquid, open the drain flange into the magnetic float, should pay attention to the heavy and magnetic end up not flip!

4, the low temperature liquefied gas and special products, vacuum jacketed insulation main body level meter, the installation process be careful not to damage the jacket, so as not to affect the quality of the products.

9, selection and installation:

1, we must first understand the equipment running their own situation, what is the measuring medium, even if they do not need to know what material, our company also can determine the material according to the medium used equipment.

2, when equipped with the remote meter to do the following, should make the remote meter to gauge leading tube, stainless steel hoop is fixed (disable iron); the remote meter should be on the surface should be oriented and close to the main duct; the remote meter should be zero and gauge zero instructions in the same horizontal line; remote meter and display instrument or computer connection need to wear protective pipe laying or shielding two core cable connection box; a wire inlet hole after laying, requires good sealing, in order to avoid rain, moisture intrusion and the remote meter can not work normally, the junction box in the repair or completion of commissioning should be timely cover.

3, according to the media, cleaning the main duct to remove impurities;

4, for more than a certain length (common type > 3 meters, 2 meters, anti-corrosion type) of the liquid level meter, need to increase the middle reinforcement flange or lug fixed support, to increase the strength and overcome their weight;

5, the installation location, should avoid the material medium or away from the import and export department, to avoid the rapid change of fluid material in local area, affecting the accuracy of liquid level measurement;

6, when debugging, should open the upper guide pipe valve, and then slowly open the valve at the lower part, so that medium smooth entry duct (to avoid the rush of media should be run in the float float, cause drama column fluctuation, affecting the display accuracy), observe the red ball magnetic flip is normal, and then close the lead pipe valve, open the drain valve so, the main duct level drops, according to the method, the operation three times, it is normal, can be put into operation (except special corrosive liquid); magnetic level gauge in the market there are other names, also called magnetic level gauge, or magnetic level gauge, also called magnetic float liquid level gauge. But they need to know the order parameter is certain, such as corrosive medium needs anticorrosive material, corrosion corrosion grade equivalent grade according to the changes of the medium. For example, the special situation of their own equipment, determine the installation mode of the magnetic level gauge, because some places do not fit or do not apply some installation methods.

Ten, matters needing attention:

1, auxiliary instrument and accessories with the specific content of the corresponding instrument and accessories see instructions.

2, to prevent a distance or move away in the process of float moves up and down in the main duct damage, lateral supporting special steel factory calibration gauge (with color logo) will hold the magnetic float. So after receiving the product or after installation, please remove the correction magnet, so that the float can move along with the liquid level, before use if the magnetic reversal of inconsistent color correction, available the magnetic suction along the instrument can work normally.

3, level meter installed, with magnetic correction of magnetic guidance once to zero below zero above display red, white display.

4, level gauge according to user needs with a heating jacket or an electric heating device, such as when ordering does not select this option, and in the installation of self used heat pipe, temperature and mixed with heat generated by the device can not exceed the rated temperature level meter.

5, level meter into travel, should open the valve on the liquid guide pipe, and then, the liquid valve open long, let the liquid medium smoothly into the main canal, avoid the liquid medium with a rapid rise caused by magnetic reversal failure or disturbed (in case of this phenomenon can be used to correct the magnet).

Eleven, the selection of encoding:

ZW-UHZ-

A series of magnetic level gauge (Zhongwei control)

 

Basic types

Fifty-one

Magnetic indicator


Fifty-two

Magnetic indicator - Remote output


A

Basic type ( Side mounted )

B

Insulation type (jacket) S Frost proof R Electric heating type

C

Insert type (top mounted)

D

Corrosion proof type (side mounted anti-corrosion type)

E

Insert (top mounted type heat insulation type)

F

Insert the anti-corrosion type (top mounted anti-corrosion type)

G

Heat resistant type


One

No alarm

Two

belt One Only the alarm point

Three

belt Two Only the alarm point

Four

belt Three Only the alarm point

Five

belt Four Only the alarm point


Five

Stainless steel

 

The main materials

Six

Corrosion protection of aluminum

Seven

titanium

Eight

PVC

Nine

PTFE package


A

-40-0 C

 

working temperature

B

Less than or equal to 80 C

C

Less than or equal to 100 C

D

Less than or equal to 150 C

E

Less than or equal to 300 C

F

Less than or equal to 350 C

G

Less than or equal to 480 C


A

0.6 Mpa


 

The actual pressure

B

1 Mpa


C

1.6 Mpa


D

2.5 Mpa


E

4.0 Mpa


F

6.3 Mpa


G

10 Mpa


H

16 Mpa


I

22 Mpa


J

32 Mpa




L

The proportion of medium (g/ M)

L

Length measurement

L

The connecting flange ( DN )

L

output signal 4-20mA

12, please provide the following data design:

1, specifications; magnetic level gauge: ZW-UHZ series;

2, the measured medium Name: medium density: if you do not know the density, can tell us the name of the medium, which is composed of mixed liquid to know several liquid;

3, the instrument measuring range: also known as nominal length, which is a flange of the center distance, or look at the scale of products already in use;

4, working pressure: pressure;

5, working temperature: measure the temperature of the liquid;

6, material requirements: wetted materials, such as do not know what kind of material, can give us advice (general liquid is what material we can use what material);

7, supporting the supply of flanges, bolts and nuts, valve, sealing washers and other accessories;

8, standard: flange flange nominal diameter, using conventional flange is DN20 or DN25;

9, special requirements: please indicate in detail before ordering, such as whether or not to take the remote, insulation jacket etc..

Customer service service commitment:

1, our level meter series products quality problems within twelve months, responsible for free maintenance.

2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.

3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.

4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.

5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.