亚洲精品一本知道高清乱码|日韩一区二区三区在线观看不卡|亚洲精品美女在线观看播放|久久一本精品久久久久99|亚洲 一区 精品 在线

Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

High temperature type radar liquid level gauge

6智能雷達(dá)液位計(高溫型)806.png
  • 6智能雷達(dá)液位計(高溫型)806.png
High temperature type of radar level gauge has a low maintenance, high performance, high precision, …

Description:

Products overview:

ZWRD806 seriesHigh temperature type radar liquid level gaugeLow transmission power extremely short of microwave by transmitting and receiving antenna system.Radar wave are running at the speed of light.Running time can be transformed into material level signal by electronic parts.A special type of time extension method can guarantee the stability of a very short period of time and accurate measurement.Even if there are false reflection, a new micro processing technology and software can accurately analyze level echo.By entering the container size, distance above the value can be converted into is proportional to the level of the signal.The instrument can short positions debugging.In the measurement of the solid application can use K - frequency high frequency sensors.Because of the signal is focused on the effect is very good, bin installation or within the warehouse wall adhesion matter will not affect the measurement.

Second, the working principle:

ZWRD806 series high temperature type radar level meter is the measuring instrument based on the principle of time travel, very low energy is emitted by a very short microwave pulse by transmitting and receiving antenna system.Radar wave are running at the speed of light.Running time can be transformed into material level signal by electronic parts.Probe a high-frequency pulse and probe the conduction along the cable type or rod type, when the pulse in the material surface reflected by the receiver inside the instrument, and the distance signal is transformed into material level signal.A special type of time extension method can guarantee the stability of a very short period of time and accurate measurement.Even if the condition is relatively complex, false echo, with zui new microprocessor technology and debug software can accurately analyze the level of the echo.

The input

Antenna receiving the reflected microwave pulse and sending them to the electronic circuit, microprocessor to signal processing, identify the micro pulse produced by the echo in the material surface.Correct echo signal recognition completed by intelligence software, precision can reach millimeter level.Distance on the surface of the material distance D is proportional to the pulse travel time T:

D=C×T/2

Where C is the speed of light

E known due to empty cans of distance, the level of L as follows:

L=E-D

The output

By entering empty cans height E (= zero), full tank height F (= full scale) and some applications to set parameters, application parameters will be automatically adapt instrument to measure the environment.Corresponding to the 4-20 ma output.

Applications:

ZWRD806 series high temperature type radar level gauge is suitable for high temperature (350 ℃), high pressure, high vacuum, steam, dust and bad environment such as volatile gas.For continuous measurement of different materials.The instrument main technical indicators meet or exceed similar products at home and abroad, and convenient installation and debugging, can use a single, also can use network, can be widely used in metallurgy, building materials, energy, petrochemical, water conservancy, food and other industries.

Four, the main features:

1, no blind area, high precision;

2, two wire system technology, it is the differential pressure instruments, magnetostriction, rf admittance, magnetic flap instrument of substitute products;

3, shall be subjected to pressure, vacuum, temperature changes, inert gas, dust, steam and other environmental impact;

4, installation is simple, durable, free maintenance;

5, the output signal is 4 ma ~ 20 ma/HART protocol, calibration is simple, through digital LCD easy calibration operation, by setting up and programming software to realize simple configuration;

6, measurement sensitivity, fast refresh;

7, suitable for high temperature working condition, process temperature up to 200 ℃, when high temperature to extend the antenna is used up to 350 ℃.

Five, the technical parameters:

1, the working frequency: 6.8 GHz;

2, measuring range: cable type: 0-35 m pole type, coaxial type: 0-6 m;

3, repeatability, plus or minus 3 mm;

4, resolution: 1 mm;

5, sample: echo sampling/s 54 times;

6, the response speed: > 0.2 S (according to the specific use of the case may be);

7, precision: < 0.1%;

8, the output current signal: 4-20 ma;

9, communication interface: HART communication protocol;

10, process connection: G1-1/2, G3/4 flange: (, DN80, DN100, 6;

11, the process pressure: 1 ~ 60 bar;

12, power: 24 VDC ripple voltage (+ / - 10%) : 1 VPP;

13, power consumption: max22.5 mA;

14, environmental conditions: temperature: - 40 ℃ ~ + 250 ℃;

15, shell protection grade: IP68;

16, explosion-proof level: EXiaIICT6;

17, two wire connection: instrument power supply and signal output sharing two core cable;

18, cable entry: M20 x 1.5 (cable diameter 5 ~ 9 mm).

Six, the debugging method:

A, can through debugging in three ways:

1, by displaying the adjustment module PM;

2, through debugging software SOFT;

3, handheld programmer by HART.

B, through SOFT software debugging:

No matter the signal output, 4-20 ma/HART, radar sensors can be through the software debugging.Is instrument with the SOFT software debugging, need a meter CONNECTCAT drives.

Using software debugging, for the radar instrument 24 VDC power up, at the same time connect HART adapter front end with a resistance of 250 ohms.If the one-piece HART resistance (250 ohm internal resistance) of electricity meter, there is no need for additional external resistance, HART adapter can and 4...20 ma line in parallel.

Seven, measurement considerations:

1, measurement range from the beam hitting a can of low starting point, but under special circumstances, if the tank is low for concave type or conical, when the level below this point cannot be measured.

2, if the medium to low dielectric constant when it is in low level, low visibility, at this time in order to ensure the accuracy of measurement, the recommendations will be zero at low altitude to the position of the C.

3, theory, measurement to achieve the position of the antenna tip is possible, but considering the corrosion and the influence of the adhesive, the final value of measuring range should be at least 100 mm distance from the tip of the antenna.

4, the overflow protection, additional on the blind spot can define a safe distance.

5, zui small measuring range related to the antenna.

6, with different concentration, foam can absorb microwaves, and it can be reflected, but under certain conditions can be measured.

7, measurement is beyond the scope of action when the measuring range beyond, instrument of 22 ma current output.

Eight, the use of requirements:

1, the installation location

Radar from the ideal location for the tank wall between radius of 1/2 to 1/3, away from the inlet port of discharge.If can not reach the ideal installation location selection radar level meter, I will try to choose more relaxed radar to installation position requirement.

2, dielectric properties

First is a solid, liquid, and medium point of dielectric constant, the greater the medium point of dielectric constant measurement radar effect, the better).Corrosion resistance, viscosity, etc.

3, the tank environment

A) good (tank without obstacles work when the environment is good).

(b) is bad there are obstacles such as mixing heating coils operating steam, crystallization, etc.).

Nine, daily check the maintenance:

1, daily inspection maintenance mainly to check the power supply voltage and output current is normal.About 30 ~ 60 min after electrify, instrument can work normally.If there is no output parameter meter, should check whether the power supply is connected to real, and check whether the fuse is burnt.

2, when using is become an organic whole repeatedly and equipment, the whole system radar level meter is sealed, so at ordinary times should also check the sealing condition of joints of different parts are in good condition.

3, radar, head of the use of the internal temperature of 65 ℃.General use cases not more than the temperature, but if the temperature of the measured medium is very high, is the temperature inside the radar head could exceed 65 ℃.At this time, can use a small amount of wind, by the phi 6 x1 copper tube rain hat head blow in radar, to internal temperature down, never to do mechanical cooling water or other liquid.

4, volatile organic compounds in crystallization or antenna, radar level gauge trumpet to timely inspection and cleaning.

Ten, parameter table:

Product category

ZWRD804

ZWRD805

ZWRD806

Product pictures

6 intelligent radar level gauge (bell) 804 PNG6 intelligent radar level gauge (high pressure type) 805. PNG6 intelligent radar level gauge (high temperature type) 806. The PNG

Range of application

Simple process conditions, granular material, block material 
Such as: 
The water tank
Acid and alkali storage tank 
Slurry storage tank 
Solid particles
Small storage tanks

Low dielectric constant or mixing liquid
Such as: 
The water tank
Acid and alkali storage tank 
Slurry storage tank 
Solid particles
Small storage tanks

Environment of high temperature solid grain measurement
Such as: 
Crude oil, light oil tank
Raw coal, pulverized coal positions
Volatile liquid storage tanks
Coke material level 
Slurry storage tank 
Solid particles

measuring The amount van wai

30m

20M optional

30m

pass cheng evenPick up

Universal flange

The flange

The flange

pass cheng wenThe degree of

- 40-250℃

- 40-250℃

- 40-250℃

pass chengpressure force

-1.0-3bar

-1.0-20bar

-1.0-40bar

heavy after sex

± 3mm

± 3mm

± 3mm

fine The degree of

< 0.1%

< 0.1%

< 0.1%

frequency The rate of van wai

6.8GHz

6.8GHz

6.8GHz

explosion-proof/Protection grade

EXiaIICT6/IP68

EXiaIICT6/IP68

EXiaIICT6/IP68

The letter No.Lose, Out of the

4…20mA/HART(The two lines)

4…20mA/HARTTwo lines)

4…20mA/HART(The two lines)

Browse:
Return To The Top

分享到: