WSSX series Electric contact remote double metal thermometer Is wound into a double sheet metal ring…
Description:
Productoverview: WSSX seriesElectric contact remote double metal thermometerIs wound into a double sheet metal ring bent on.At the end of heating expansion, drives the pointer to rotate, the instrument will display the temperature value, and prevent environmental vibration in double metal thermometer internal filling silicone oil or double metal thermometer display separation part and a measuring part to achieve the seismic effect.Electric contact bimetallic thermometer and integrated seismic electric contact bimetallic thermometer and separate seismic electric contact bimetallic thermometer 2. Two, work principle: WSSX seriesElectric contact remote double metal thermometerElectrical contact device with mechanical electric contact.When the medium temperature changes, on the free end of the thin shaft and steering transmission mechanism to drive the movable contact and pointer rotation, indicating in the dial on the change of temperature value, and when the fixed contacts (upper and lower fixed contacts) instantaneous contact or disconnection of the relay and contactor circuit in the system, in order to achieve the purpose of automatic control and alarm. Three, application: WSSX seriesElectric contact remote double metal thermometerIs a measuring instrument used in temperature field production is not very high occasions, can be directly measured gas, steam temperature, temperature measurement at 80 degrees -500 degrees below zero within the scope of the paragraph from the design has the characteristics of waterproof, corrosion resistance, shock resistance, intuitive readings, sturdy and durable, widely used in petroleum the chemical, ships, machinery, power, textile, printing and other industrial occasions. Four, main features: 1, the scene display temperature, convenient safe and reliable, long service life; 2, a variety of forms, can meet different requirements.Victims of mercury free, easy reading, strong shock. 3, the protection pipe of 1Gr18Ni9Ti stainless steel and two molybdenum titanium, pressure, strong corrosion resistance. 4, core pulling type thermometer can not stop short time maintenance or replacement of movement. 5, integrated with axial type, radial type, 135 type, universal type, complete varieties, suitable for various on-site installation need. Five, technical parameters: 1, measurement range: -80~40 degrees, -40~80 degrees, 0~50, 100, 150, 200, 250 degrees, or specified by the user; 2, precision class: 1.5; 3, working pressure: Zui pressure 4.0Mpa; 4, F4 coating thickness: ~0.8mm, can also be specified by the user; 5, quality inspection by EDM micro flaw detection, voltage 12KV, frequency of 1.6 * 106Hz breakdown; 6, material: ICr18Ni9Ti; metal protection tube or specified by the user; 7, metal protection tube: phi 6, Phi 8, Phi 10, Phi 12; 8, connecting dimensions: (1) movable external thread: M27 * 2, G3/4, G1/2, or specified by the user; (2): DN15, 20, flange 25, HG20593, or specified by the user; 9, dial od: D= Phi 80, Phi 100, Phi 150.
Note: 1, in storage, installation, use and transport process, to avoid the collision protection tube, prohibit the protection tube bending and deformation. 2, installation, non twist instrument shell. 3, the instrument shall work normally in the -30 to 80 DEG C ambient temperature. 4, the instrument can often work in the temperature scale range 1/2 ~ 3/4. 5, the protective tube immersionmedium measured in length must be greater than the length of the sensing element, this is done in order to ensure the accuracy of measurement. 6, do not use media exposure in measuring container. 7, the use of the process should pay attention to check in time, probably in about 6 months.
Seven, electrical parameters:
Rated power (VA)
Working voltage (V)
Allow the current (A)
Ten
220VAC
0.7A
24VDC
Eight, insulation resistance:
Rated voltage
DC voltage test (DC)
insulation resistance
24VDC
One hundred
Seven
220VAC
Five hundred
Twenty
Normal working conditions: air temperature-25-+55Temperature relative humidityLess than 85%. Set point error: set point error should not exceed the basic error limitOne.FiveTimes. Switching difference: switching error should not exceed the basic error limitOne.FiveTimes. Nine, technical data sheet:
Model
The measuring range of C
Precision grade
Protection tube material
The specification of L (mm).
Mounting and fixing device
WSSX-400
-40-+80
0-+50
0-+100
0-+150
0-+200
0-+300
0-+400
0-+500
One point five
1Cr18Ni9Ti
Three hundred and four
Three hundred and sixteen
316L
Hastelloy C-276
Seventy-five
One hundred
One hundred and fifty
Two hundred
Three hundred
Four hundred
Five hundred
Seven hundred and fifty
One thousand
No fixed device
WSSX-410
WSSX-480
WSSX-401
Movable external thread
WSSX-411
WSSX-481
WSSX-402
The movable internal thread
WSSX-412
WSSX-482
WSSX-403
Fixed thread
WSSX-413
WSSX-483
WSSX-404
Fixed flange
WSSX-414
WSSX-484
WSSX-405
Card set screw
WSSX-415
WSSX-485
WSSX-406
Sleeve flange
WSSX-416
WSSX-486
Ten, the selection of encoding:
Serial number
category
Specifications
Explain
WSS
X
Electric contact type
Double metal thermometer (Zhongwei control)
Dial diameter
-3
Phi 60
-4
Phi 100
-5
Phi 150
Dial form
Zero
The axial (straight)
One
Radial (angle)
Two
135 degrees to (an obtuse type)
Eight
Universal (angle adjustable type)
Fixed form
Zero
No fixed device
One
Movable external thread
Two
The movable internal thread
Three
Fixed thread
Four
Fixed flange
Five
Card set screw
Six
Sleeve flange
Type of protection
-
Ordinary type
W
Type of protection
F
Anti-corrosion type
Example: universal type, dial diameterPhi 100The temperature range.Zero~Four hundredC,One point fiveActivity level, external threadM27 * 2Length.450mm.WSSX-481,Zero~Four hundredC,L=450,M27 * 2,One point fiveClass.
Eleven,Design selection and ordering information: 1, model; 2, precision grade; 3, temperature range; 4, fixed form; 5, the installation form of casing heat; 6, the inserted length. Customer service service commitment: 1, my company sold ZhongweiThermometer seriesThe product within twelve months of quality problems, responsible for free maintenance. 2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement. 3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost. 4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost. 5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.