亚洲精品一本知道高清乱码|日韩一区二区三区在线观看不卡|亚洲精品美女在线观看播放|久久一本精品久久久久99|亚洲 一区 精品 在线

Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
0517-86918678
Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
Tel:0517-86918678
Fax:0517-86918679
Email:zhongweick@163.com
Post Encoding:211600

Armor thermal resistance

16鎧裝式鉑電阻.jpg
  • 16鎧裝式鉑電阻.jpg
WZPK series Armor thermal resistance Is a kind of temperature sensor, it is assembled with thermal r…

Description:

Productoverview:
WZPK series Armor thermal resistance Is a kind of temperature sensor, it is assembled with thermal resistance of small diameter, easy bending, good shock resistance, suitable for installation can not be installed in the assembly type heat resistance occasions, with the introduction of temperature components of thermal resistance so accurate, sensitive and fast thermal response time, stable quality, long life and so on. The outer protective sleeve adopts stainless steel, filled with high density oxide insulator material, therefore, sheathed thermal resistance has strong anti pollution performance and mechanical strength, suitable for installation in harsh environment applications.

Two, work principle:
WZPK series Armor thermal resistance Under the action of temperature, thermal resistance wire resistance change with change, show resistance meter will instruct the thermal resistance value generated by the corresponding temperature value.
Three, application:
WZPK series Armor thermal resistance Can be used for temperature measurement within the range of -200-600 DEG C, can be directly used for copper wire and the two instrument used to connect with power good output characteristics, for display instrument, recorder, regulator, scanner, data recorder and computer to provide accurate temperature signal.

Four, main features:
1, fast thermal response time, reduce the dynamic error;
2, small diameter, length is not limited;
3, high measuring accuracy;
4, imported film resistor, stable and reliable performance.
Five, thermal response time:
In the temperature step change occurred, the output variation of the thermal resistance to the equivalent of the 50% step change time required that the response time is hot, denoted by t0.5.
Six, the nominal pressure:
Generally refers to the normal temperature, protection tube can withstand static pressure without rupture, 1.5 times of the test pressure generally adopts the nominal pressure. In fact, not only allow the nominal pressure and protection of pipe material, diameter, wall thickness, but also the structure, installation, and the insertion depth of the measured medium velocity, the kinds of.
Seven, the thermal resistance of insulation resistance:
1, room temperature insulation test voltage resistance is 10 ~ 100V DC arbitrary value, environmental temperature is over 15~35 DEG C, relative humidity should be less than 80% at room temperature, the insulation value should be not less than 100M.
2, the thermal resistance allowed by current:
3, by measuring the current Zui platinum resistance is less than 5mA.
Note: on this type of specific technical requirements (such as simple terminal, splash proof junction box, waterproof type connection box etc.) contact with the company.

Eight, technical parameters:
Product executive standard:
IEC751;
JB/T8623-1997;
JB/T8622-1997;
Insulation resistance at room temperature;
Heat resistance at ambient temperature is 15 to 35 DEG C, relative humidity is less than 80%, the test voltage is 10 - 100V (DC) >100M. The insulation resistance between electrode and outer tube.

Nine, installation method:
1, first of all should measure the good thermal resistance thread thread or flange size, supporting flange or thread processing base.
2, according to the size of the base flange or threaded hole in the pipe, to be measured.
3, the flange or the screw tooth of the welding. The flange or thread is inserted has opened hole in the flange or threaded seat base and pipeline measured welding.
4, the screw base thermal resistance with bolts or threaded in has been welded.
5, according to the wiring diagram of the terminal box thermal resistance grounding line, and the display instrument is connected on the dial corresponding. Connection box can not contact with the wall of the measured medium pipeline, ensure the junction box temperature does not exceed the range of 100 DEG C. Outlet hole junction box should prevent due to poor sealing water vapor, dust deposition caused by short circuit terminal.

10, installation notes:

For the installation of thermal resistance; thermal resistance should pay attention to several details in the installation and use; for the temperature measurement is accurate, safe and convenient maintenance, and does not affect the equipment operation and production operation. To meet the following requirements, in the selection of installation site of thermal resistance and insertion depth should pay attention to the following 2 points:
1, with a protective casing with heat transfer thermal resistance and heat loss, in order to reduce the measurement error, the thermal resistance should have sufficient depth of insertion:
A, when measuring the original insertion depth is more than 1m, should be installed vertically, or installing supporting frame and a protective sleeve.
B, if you need to measure the flue gas temperature is, while the flue diameter is 1000mm, the thermal resistance can insert depth 500mm.
Heat resistance C, temperature measurement for fluid pipe center, generally the measuring end is inserted into the pipe center (vertical or inclined installation). If the measured fluid pipe diameter is 100 mm, the thermal resistance should choose the insertion depth of 50~100 mm (should take into account the size installation base or flange).
D, for temperature measurement of high temperature and high pressure and high speed fluid (such as main steam temperature), in order to reduce resistance to the fluid and prevent the protective sleeve to protect the casing fracture under the influence of the fluid, can take the protection tube or shallow inserted by thermal sleeve type heat resistance. Shallow inserted heat resistance protection sleeve type, which is inserted into the main steam pipe depth should be less than 75mm; thermal sleeve type thermal resistance standard insert depth 100mm.
2, in order to make the measuring end of thermal resistance and the measured full heat exchange medium, should choose a reasonable measuring position, to avoid the valve, elbow and piping and equipment installed near dead heat resistance.

11, measurement range and tolerance:

Model

Graduation

The temperature range of C DEG

Precision grade

Tolerance

WZPK

Pt100

-200-+500

A

(0.15+0.002 + LTL)

WZPK

Pt100

-200-+500

B

(0.30+0.005ltl).

Twelve, thermal response time:

The diameter of the casing

Thermal response time

With 3

Less than or equal to 3

With 4

Less than or equal to 5

With 5

Less than or equal to 8

With 6

Less than or equal to 12

With 8

Less than or equal to 15

Thirteen, selection table:

Code

WZ - K - - - - - - - - - - - - /

W

Temperature meter (Zhongwei control)


Code


Z

Heat resistance


Code

The temperature measuring element

P

Pt100 Pt1000 (the order required)

C

Cu50


Code


K

Armoured type (assembled the symbol)


Code



Single

Two

Double branch


Code

Installation assembly (armoured)

Zero

No protection tube

One

No fixed device

Two

Fixed thread

Three

Movable flange

Four

Fixed flange

Five

90 degree angle flange

Six

Fixed thread taper

Code

Installation of armor type

One

No fixed device

Two

The fixed clip sleeve thread

Three

Flecible thread

Four

The fixed clip sleeve flange

Five

The movable ferrule flange


Code

Connection box

Zero

Simple type

One

Ordinary type

Two

Splash proof (waterproof type substitution)

Three

Waterproof type

Four

Explosion proof type

Six

Socket type

Seven

With the connecting wire type


Code

Armoured armoured body diameter

Three

Phi 3mm

Four

Phi 4mm

Five

Phi 5mm

Six

Phi 6mm

Eight

Phi 8mm

Code

The diameter of the outer protection tube assembly (full armor)

Zero

Phi 16mm

One

Phi 12mm

For example: A, Ptl00, B, fixed thread M16 * 1.5, length 450mm, length of 300mm. WZPK-223, Ptl00, L:450 * 300, B * 1.5., M16

Fourteen, design and ordering:
1, model;
2, division no.;
3, precision grade;
4, fixed form;
5, the length or depth of insertion.
Customer service service commitment:
1, my company sold Zhongwei Thermal resistance series The product within twelve months of quality problems, responsible for free maintenance.
2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


Browse:
Return To The Top

分享到: