亚洲精品一本知道高清乱码|日韩一区二区三区在线观看不卡|亚洲精品美女在线观看播放|久久一本精品久久久久99|亚洲 一区 精品 在线

Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
0517-86918678
Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
Tel:0517-86918678
Fax:0517-86918679
Email:zhongweick@163.com
Post Encoding:211600

Explosion-proof thermal resistance

6防爆型熱電阻(法蘭式)01.png
  • 6防爆型熱電阻(法蘭式)01.png
WZP-240 series Explosion-proof thermal resistance The structure, principle and assembly of thermal r…

Description:

Productoverview:

WZP-240 series Explosion-proof thermal resistance The structure, principle and assembly of thermal resistance is basically the same, the difference is, flameproof or intrinsically safe explosion-proof junction box products (shell) special structure is adopted in the design, wiring box with high strength Aluminum Alloy die casting, and has sufficient internal space, wall thickness and mechanical strength, thermal stability of rubber seal the rings are in line with national standards. So, when the explosive mixed gases inside the enclosure when the explosion occurred, the internal pressure will not destroy the junction box, and the resulting heat is not the outward diffusion of detonation.

Two, work principle:
WZP-240 series Explosion-proof thermal resistance The gap explosion-proof junction box component design principle, with sufficient strength, all can produce a spark, arc and dangerous temperature components are sealed in a box cavity, when the cavity when the explosion occurred, the joint gap flameout and cooling, so that the explosion flame and temperature transmission to the outside of the cavity, thereby temperature measurement.
Three, application:
WZP-240 series Explosion-proof thermal resistance Usually, record and display instruments using instruments, electronic computing and other supporting. Direct measurement of hydrocarbons in the production site and other explosives -200 ~ C~500 ~ C range of liquid, steam and gas and solid surface temperature.
Four, main features:
1, various forms of explosion-proof, explosion-proof performance;
2, large measuring range;
3, high mechanical strength, good pressure resistance.
4, a spring type temperature sensing element, good seismic performance;
Five, technical parameters:
Product executive standard
IEC751
JB/T18622-1997
JB/T8623-1997
JB/T5518-91
Insulation resistance at room temperature
Heat resistance at ambient temperature is 15 to 35 DEG C, relative humidity is less than 80%, the test voltage is 10 - 100V (DC) >100M. The insulation resistance between electrode and outer tube.

Six, installation method:
1, first of all should measure the good thermal resistance thread thread or flange size, supporting flange or thread processing base.
2, according to the size of the base flange or threaded hole in the pipe, to be measured.
3, the flange or the screw tooth of the welding. The flange or thread is inserted has opened hole in the flange or threaded seat base and pipeline measured welding.
4, the screw base thermal resistance with bolts or threaded in has been welded.
5, in accordance with the wiring diagram of the terminal box thermal resistance grounding line, and the display instrument is connected on the dial corresponding. Connection box can not contact with the wall of the measured medium pipeline, ensure the junction box temperature not exceeding 100 DEG C. Outlet hole junction box should prevent due to poor sealing water vapor, dust deposition caused by short circuit terminal.

Seven, measurement range and tolerance:

Model

Graduation

The temperature range of C DEG

Precision grade

Tolerance

WZP240

Pt100

-200-+500

A

(0.15+0.002 + LTL)

WZC240

Pt100

-200-+500

B

(0.30+0.005ltl).

Eight, selection table:

Code

WZ - - - - - - - - - - - - - / - armored thermal resistance

W

Temperature meter (Zhongwei control)


Code


Z

Heat resistance


Code

The temperature measuring element

P

Pt100 Pt1000 (the order required)

C

Cu50


Code


K

Armoured type (assembled the symbol)


Code



Single

Two

Double branch


Code

Installation assembly (armoured)

Zero

No protection tube

One

No fixed device

Two

Fixed thread

Three

Movable flange

Four

Fixed flange

Five

90 degree angle flange

Six

Fixed thread taper

Code

Installation of armor type

One

No fixed device

Two

The fixed clip sleeve thread

Three

Flecible thread

Four

The fixed clip sleeve flange

Five

The movable ferrule flange


Code

Connection box

Zero

Simple type

One

Ordinary type

Two

Splash proof (waterproof type substitution)

Three

Waterproof type

Four

Explosion proof type

Six

Socket type

Seven

With the connecting wire type


Code

Armoured armoured body diameter

Three

Phi 3mm

Four

Phi 4mm

Five

Phi 5mm

Six

Phi 6mm

Eight

Phi 8mm

Code

The diameter of the outer protection tube assembly (full armor)

Zero

Phi 16mm

One

Phi 12mm

Heat resistance A By ordering protocol.

Note: the connector form, convenient installation, suitable for measuring -200-450 Liquid, gas and solid surface temperature range.

The design and selection of notes:
1, model;
2, division no.;
3, precision grade;
4, fixed form;
5, the length or depth of insertion.
Customer service service commitment:
1, my company sold Zhongwei Thermal resistance series The product within twelve months of quality problems, responsible for free maintenance.
2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


Browse:
Return To The Top

分享到: