Handheld intelligent signal generation verifier
Products overview:
ZW - Y200A series handheld smart verification strong and perfect function, of output signal can make your leisurely at the scene of the tense construction process for a variety of instrument calibration and commissioning.And in terms of two wire instrument calibration, showed its superiority.Can stably according to 20.000 (5 significant figures) value.As it has the multi-function, more features, the characteristics of high performance, so is a necessary tool in industrial control process of the measurement.All functions are designed to be very easy to use.And its structure is professional designed for field use, single hand operation, and only single hand instruments all adjust the Settings.
Second, the widely used:
ZW - Y200A seriesHand-held intelligent signal checkIs a kind of intelligent instrument verification, high precision, small volume, can be used in the field of industrial instrumentation calibration, also can be used in the calibration of laboratory instruments and meters.Powerful, can simulate the output to a variety of industrial control in the process of measurement and control signals, and at the same time also can measure these occurring in the process of industrial control signal.
Three, hand-held intelligent signal occurred verification key features:
1, provide DC24V circuit of power supply, directly adjusted two wire measurement instrument;
2, 5 LCD display;
3, high precision, 0.05%;
4, automatic range, can effectively improve the precision;
5, the built-in battery, a charge can work 20 hours (Ni MH battery);
6, frequency measurement resolution can reach 0.01 Hz;
7, 20.000 mA, such as 5.0000 V display five readings.
Four, hand-held intelligent signal occurred verification technology parameters:
1, the input resistance:
Current file: 10 Ω;
Voltage profile: 10 m Ω;
Frequency shift: 1 m Ω;
Millivolt file: 1000 m Ω.
2, load characteristics:
Current file: RL 1.5 K or less Ω 0 ~ 10 ma;
Voltage profile: RL Ω 5 k or higher;
A frequency shift RL 5 k or more Ω;
Millivolt file: RL Ω 5 k or higher frequency;
Input waveform: square wave, sine wave, triangle wave, pulse (Ton uS or higher);
Input frequency sensitivity: the Vp - p p 300 mv 1000 KHZ;
Temperature: 0 ℃ to 50 ℃;
Overall dimensions: 190 x 95 x 40 mm;
Ambient temperature, relative humidity of 90% or less, without condensation;
Weight: 380 g (including battery).
Five, the technical indicators:
range | The maximum | precision |
500.00mV | 60V | 0.05%+3d |
5.0000V | 0.05%+3d | |
50.000V | 0.05%+3d | |
20.000mV | 240mV | 0.05%+3d |
200.00mV | 0.05%+2d | |
20.000mA | 240mA | 0.05%+2d |
200.00mA | 0.05%+2d | |
0-500KHz Five automatic range | 650KHz | 0.15%+1d |
Vi.Output indicators:
range | The maximum | precision |
500.00mV | 60V | 0.05%+3d |
5.0000V | 0.05%+3d | |
200.00mV | 240mV | 0.05%+5d |
20.000mA | 24mA | 0.05%+2d |
2.0000KHz | 22KHz | 0.05%+3d |
20.000KHz | 0.05%+3d |
Product warranty and after-sales service:
ZW series - Y200A hand-held intelligent signal check product quality assurance period for 12 months, life-long maintenance.Warranty period for the damage, free maintenance, more than warranty, maintenance fee and shipping fee only.To new users first use, generally by the menu function prompts the operation, there are technical difficulties, please call the company technical department to give answers. Company can send engineers to the scene to guide if necessary.