Irradiation crosslinking polyethylene insulated cable (wire)

輻照交聯(lián)聚乙烯絕緣電纜.jpg
  • 輻照交聯(lián)聚乙烯絕緣電纜.jpg
Irradiation crosslinking polyethylene insulated cables (wires) flame retardant products superior per…

Description:

One, the cable's brief introduction:
Irradiation crosslinking polyethylene insulated cables (wires) flame retardant products superior performance, little smoke during burning, no corrosive gas escape, widely used in nuclear power station, subway station, telephone system and computer control center, high-rise buildings, hotels, radio and television, important military facilities, oil platform, etc., as well as personnel is relatively concentrated, low air density.
Second, the irradiation crosslinking polyethylene insulated cable (wire) using features:
1. Don't delay flammability and flame retardancy.
2. The little amount of smoke during burning, do not produce poisonous gas, no corrosive gas.
3. Has a certain mechanical electrical and physical properties, and can satisfy the use requirement of the cable.
Three, product standards:
TICW/06—2009 YD/T 1173 GB9330-88 、IEC601034。 
Four, irradiation crosslinking polyethylene insulated cable (wire) model name:
1.Low smoke zero halogen flame retardant power cable

model
The name of the
YE
Polyethylene insulation, low smoke zero halogen flame retardant polyolefin sheathed power cable
YJE
Irradiation crosslinking polyethylene insulation, low smoke zero halogen flame retardant polyolefin sheathed power cable
YWE
Low smoke zero halogen flame retardant polyolefin insulation, low smoke zero halogen flame retardant polyolefin sheathed power cable
YJWE
Irradiation crosslinking of low smoke zero halogen flame retardant polyolefin insulation, low smoke zero halogen flame retardant polyolefin sheathed power cable
YE23
Polyethylene insulation tape armored low smoke zero halogen flame retardant polyolefin sheathed power cable
YJE23
Irradiation crosslinking polyethylene insulation steel tape armoured with low smoke zero halogen flame retardant polyolefin sheathed power cable
YWE23
Low smoke zero halogen flame retardant polyolefin insulation tape armored low smoke zero halogen flame retardant polyolefin sheathed power cable
YJWE23
Irradiation crosslinking of low smoke zero halogen flame retardant polyolefin insulation tape armored low smoke zero halogen flame retardant polyolefin sheathed power cable

2.Low smoke zero halogen flame retardant computer cable

model
The name of the
DJYY(R)P
Low smoke zero halogen flame retardant polyolefin insulated and sheathed wire weaving total screen computer shielded cable (soft)
DJYPY(R)
Low smoke zero halogen flame retardant polyolefin insulated and sheathed wire woven split screen computer shielded cable (soft)
DJYPY(R)P
Low smoke zero halogen flame retardant polyolefin insulated and sheathed wire woven split screen a total screen computer shielded cable (soft)
DJYY(R)P2
Low smoke zero halogen flame retardant polyolefin insulated and sheathed copper tape around the total screen computer screen (soft) cables
DJYP2Y(R)
Low smoke zero halogen flame retardant polyolefin insulated and sheathed copper tape around the package split screen computer shielded cable (soft)
DJYP2Y(R)P2
Low smoke zero halogen flame retardant polyolefin insulated and sheathed copper tape around the package split screen a total screen computer shielded cable (soft)
DJYDYD(R)P3
Low smoke zero halogen flame retardant polyolefin insulated and sheathed aluminum-plastic composite belt around the total screen computer screen (soft) cables
DJYDP3YD(R)
Low smoke zero halogen flame retardant polyolefin insulated and sheathed aluminum-plastic composite belt winding and split screen computer shielded cable (soft)
DJYDP3YD(R)P3
Low smoke zero halogen flame retardant polyolefin insulated and sheathed aluminum-plastic composite belt winding and split screen a total screen computer shielded cable (soft)
Steel tape armoured cable plus 22 after model, shielding can be used tin plated copper wire, the basic model is slightly

3.Low smoke zero halogen flame retardant control cable

model
The name of the
KYY
Copper low smoke zero halogen flame retardant polyolefin insulated and sheathed control cable
KYYR
Copper low smoke zero halogen flame retardant polyolefin insulated and sheathed control cable
KYYP
Copper low smoke zero halogen flame retardant polyolefin insulated and sheathed copper wire braided shielding control cable
KYYRP
Copper low smoke zero halogen flame retardant polyolefin insulated and sheathed wire braided shielding control cable
KYYP2
Copper low smoke zero halogen flame retardant polyolefin insulated and sheathed copper tape screened control cable
KYYRP2
Copper low smoke zero halogen flame retardant polyolefin insulated and sheathed copper tape screened control flexible cable
KYY-22
Copper low smoke zero halogen flame retardant polyolefin insulation and sheath steel tape armoured control cable
KYYP22
Copper low smoke zero halogen flame retardant polyolefin insulated and sheathed wire weaving BingBiGang sheathed control cable
KYYP2-22
Copper low smoke zero halogen flame retardant polyolefin insulated and sheathed copper belt BingBiGang belt sheathed control cable
Note: the basic model of insulation and sheath and YDJ low smoke zero halogen flame retardant crosslinked polyolefin